CWE-142Weakness · CWE-142

CVE-2025-1774

MEDIUM · 6.3 CVSS v4.0 Published 2025-03-17
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
72/100
Remediation priority · Elevated
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Incorrect string encoding vulnerability in NASK - PIB BotSense allows injection of an additional field separator character or value in the content of some fields of the generated event. A field with additional field separator characters or values can be included in the "extraData" field.This issue affects BotSense in versions before 2.8.0.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

A string encoding vulnerability in NASK PIB BotSense allows injection of additional field separator characters or values into the content of certain generated event fields, specifically the extraData field. This improper encoding could allow attackers to manipulate event data structure, potentially causing parsing errors or data injection when events are processed by downstream systems.

MitigationUpgrade BotSense to version 2.8.0 or later to obtain the corrected string encoding. Prior to production deployment, validate that event generation and parsing functions correctly handle fields containing separator characters.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
Authentication
X
User interaction
None
Scope
X

CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify BotSense installation and version
    Locate the BotSense installation directory and check the version file or binary (commonly found in /opt/botsense, /usr/local/botsense, or the application's version flag such as 'botsense --version' or 'python -m botsense --version')
    Affected if The installed version is below 2.8.0 or the version cannot be determined
  2. Verify extraData field generation is in use
    Search configuration files (botsense.conf, config.yaml, config.json) for event generation settings or inspect the application's runtime behavior to confirm events with extraData fields are being generated
    Affected if The application generates events containing an extraData field and the BotSense version is below 2.8.0
  3. Inspect event output for separator character integrity
    Capture or review generated event output (log files, message queue, API responses) and examine the extraData field contents for unexpected field separators (commas, pipes, semicolons, or unusual characters that could indicate injection)
    Affected if Events contain extraData with unexpected separator characters or malformed structure that does not match the expected encoding pattern
  4. Review downstream system logs for parsing errors
    Check logs from systems consuming BotSense events (SIEM, log aggregators, custom consumers) for parsing failures, data validation errors, or unexpected data format warnings related to BotSense event processing
    Affected if Downstream systems report parsing errors or data anomalies specifically for BotSense-generated events containing extraData fields

A user is affected if BotSense version is below 2.8.0 AND the extraData event field generation feature is in active use, or if evidence of separator injection appears in event output or downstream parsing logs.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Upgrade BotSense to version 2.8.0 or later to obtain the corrected string encoding. Prior to production deployment, validate that event generation and parsing functions correctly handle fields containing separator characters.

Recommended fix Moderate confidence

2.8.0

  1. Identify the current BotSense version in use
  2. Download BotSense version 2.8.0 or later from the official NASK repository
  3. Backup the current BotSense configuration and data
  4. Upgrade BotSense to version 2.8.0 following the standard upgrade procedure
  5. Verify the installation and test that the string encoding vulnerability is resolved
  6. Monitor logs to confirm normal operation

Generated from the published advisory — verify against the referenced sources before acting.

Have this fixed Scoped from the published advisory
  • Consultation2.0 h
  • Implementation1.0 h
  • Testing3.0 h
  • Review / QA2.0 h
8.0 hours of engineering $1,390
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $2,224.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2025-1774 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2025-1774 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data