CVE-2025-1789
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedLocal privilege escalation in Genetec Update Service. An authenticated, low-privileged, Windows user could exploit this vulnerability to gain elevated privileges on the affected system.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · moderate confidenceLocal privilege escalation vulnerability in Genetec Update Service allows an authenticated, low-privileged Windows user to gain elevated (administrator/SYSTEM) privileges on the affected system. The vulnerability exists in the Update Service component and likely involves improper privilege handling or insecure file/service permissions that can be exploited by a local authenticated attacker.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data< 2.10.6CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Local
- Complexity
- Low
- Privileges
- Low
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Verify Genetec Update Service is installedOpen Windows Services (services.msc) and look for 'Genetec Update Service' or check Program Files for Genetec installation directories. Alternatively, run: Get-Service -Name '*Genetec*' or check registry at HKLM\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall for Genetec entries.Affected if The service named 'Genetec Update Service' or 'Genetec Update Service (GUS)' is found on the system.
-
Determine installed version of Genetec Update ServiceCheck the version of the installed Genetec Update Service executable. Common paths include C:\Program Files\Genetec\Genetec Update Service\ or C:\Program Files (x86)\Genetec\Genetec Update Service\. Right-click the executable (often named UpdateService.exe or similar) and view Properties > Details, or use PowerShell: Get-Item 'C:\Program Files\Genetec\Genetec Update Service\*.exe' | Select-Object Name, Version.Affected if The version number displayed is lower than 2.10.6 (for example, 2.10.5, 2.9.x, etc.).
-
Inspect service configuration and permissionsOpen Services (services.msc), right-click the Genetec Update Service, select Properties, and examine the 'Log on' tab. Also check service ACLs using PowerShell: Get-Acl 'HKLM\SYSTEM\CurrentControlSet\Services\GenetecUpdateService' | Format-List. Use icacls.exe on the service executable directory to review file permissions.Affected if The service runs under a privileged account (like LocalSystem or Administrator) AND low-privileged users have write/modify access to the service executable, its configuration files, or the directory where the service resides.
-
Verify service is currently runningIn Services console, check if Genetec Update Service shows a 'Running' status. Alternatively, run: Get-Service -Name '*Genetec*' | Select-Object Status, Name.Affected if The service is installed AND running (or set to start automatically) on the system.
A system is affected if Genetec Update Service is installed with a version lower than 2.10.6 and runs with elevated privileges while allowing low-privileged users to modify service files or configurations.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
dbcve · scoped2.10.6
Apply the vendor-supplied patch for CVE-2025-1789 to all affected Genetec installations as soon as possible. In the interim, limit low-privileged user access to the Genetec Update Service and monitor for suspicious process execution.
Genetec Update Service 2.10.6
- Identify the current version of Genetec Update Service installed on the system
- Download Genetec Update Service version 2.10.6 or later from the official Genetec downloads portal or through your authorized Genetec representative
- Stop any services or processes related to Genetec Update Service before upgrading
- Run the installer for the new version with appropriate administrative privileges
- Follow the installation wizard prompts to complete the upgrade
- Restart the Genetec Update Service and verify the service is running correctly
- Confirm the installed version is 2.10.6 or later using the service's version information
Generated from the published advisory — verify against the referenced sources before acting.
- Consultation3.0 h
- Implementation4.0 h
- Testing3.0 h
- Review / QA2.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $3,408.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-1789 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-1789 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data