CWE-367Weakness · CWE-367

CVE-2025-20074

HIGH · 7.8 CVSS v3.1 Published 2025-08-12
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
80/100
Remediation priority · High
Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Time-of-check Time-of-use race condition for some Intel(R) Connectivity Performance Suite software installers before version 40.24.11210 may allow an authenticated user to potentially enable escalation of privilege via local access.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

A time-of-check time-of-use (TOCTOU) race condition exists in the Intel Connectivity Performance Suite installer software versions prior to 40.24.11210. An authenticated local attacker can exploit the race window between privilege check and privilege use during installation to gain elevated privileges on the system.

MitigationUpgrade Intel Connectivity Performance Suite installer to version 40.24.11210 or later to address the race condition vulnerability.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Local
Complexity
Low
Privileges
Low
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Check if Intel Connectivity Performance Suite is installed
    Look for the software in Add/Remove Programs (Windows) or check the installation directory typically at C:\Program Files\Intel\Connectivity Performance Suite or C:\Program Files (x86)\Intel\Connectivity Performance Suite
    Affected if The software is present on the system
  2. Locate the installer executable
    Find the installer file (often named something like ICPSInstaller.exe or similar) in the installation directory, or check Windows Installer logs in %temp% for recent Intel installation entries
    Affected if An installer executable exists on the system
  3. Retrieve the installer version
    Right-click the installer executable, select Properties, and view the Details tab for the Product Version field; alternatively, use PowerShell: Get-Item 'C:\Program Files\Intel\Connectivity Performance Suite\*Installer*.exe' | Select-Object Name, VersionInfo
    Affected if The version shown is less than 40.24.11210 (such as 40.x.x.x versions below 40.24.11210 or earlier version numbers)
  4. Verify installed software version via Windows Registry
    Open Registry Editor and navigate to HKLM\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall\, search for entries named Intel Connectivity Performance Suite; check the DisplayVersion value
    Affected if The DisplayVersion value is lower than 40.24.11210

If Intel Connectivity Performance Suite installer or installed software version is found and is below 40.24.11210, the system is vulnerable to the TOCTOU race condition during installation.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Upgrade Intel Connectivity Performance Suite installer to version 40.24.11210 or later to address the race condition vulnerability.

Recommended fix Moderate confidence

Version 40.24.11210 or later

  1. 1. Identify the currently installed version of Intel(R) Connectivity Performance Suite on the system
  2. 2. Navigate to the official Intel support or download page for Intel Connectivity Performance Suite
  3. 3. Download version 40.24.11210 or a later stable release
  4. 4. Follow Intel's standard upgrade/installation procedure for the software
  5. 5. Verify the installed version matches or exceeds 40.24.11210 after completion

Generated from the published advisory — verify against the referenced sources before acting.

Have this fixed Scoped from the published advisory
  • Consultation2.0 h
  • Implementation4.0 h
  • Testing3.0 h
  • Review / QA1.0 h
10.0 hours of engineering $1,750
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $2,800.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2025-20074 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2025-20074 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data