CVE-2025-20100
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedImproper access control in the memory controller configurations for some Intel(R) Xeon(R) 6 processor with E-cores may allow a privileged user to potentially enable escalation of privilege via local access.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · moderate confidenceThis vulnerability involves improper access control in the memory controller configurations of Intel Xeon 6 processors with E-cores. A privileged local user can potentially exploit this to escalate their privileges, likely by accessing or modifying memory controller settings they should not have permission to modify.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Local
- Complexity
- High
- Privileges
- High
- User interaction
- None
- Scope
- Changed
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify the processor modelRun 'wmic cpu get name,numberofcores,numberoflogicalprocessors' on Windows or 'cat /proc/cpuinfo | grep -E "model name|cpu cores"' on Linux. Look for "Xeon 6" or "Intel(R) Xeon(R)" followed by a 6-series designation.Affected if The processor is an Intel Xeon 6 processor with E-cores (efficient cores). E-cores indicate a hybrid architecture with both performance (P-cores) and efficiency (E-cores) cores.
-
Confirm hybrid core architectureCheck system information for core type differentiation. On Windows, use 'wmic cpu get description' or check BIOS settings for P-core/E-core enumeration. On Linux, examine 'lscpu' output for 'CPU(s):' topology showing multiple core types, or check '/sys/devices/system/cpu/cpu0/topology/' for core type indicators.Affected if The system shows a hybrid architecture with both P-cores and E-cores, confirming the Xeon 6 with E-cores variant.
-
Check firmware/BIOS versionOn Windows, run 'wmic bios get smbiosbiosversion' or check via 'msinfo32'. On Linux, run 'dmidecode -s bios-version' or check '/sys/class/dmi/id/bios_version' if available. Record the current firmware version for comparison against Intel-provided fixes when released.Affected if The firmware/BIOS version is earlier than the corrected version Intel releases for this vulnerability. No fixed version is currently listed in available CVE data.
-
Review memory controller access controlsOn Windows, check 'secpol.msc' -> Local Policies -> User Rights Assignment for any modifications to privileges affecting hardware configuration access. On Linux, review '/etc/security/permissions' or equivalent. Look for any non-standard users or groups granted access to memory controller or hardware management utilities.Affected if Non-administrative users or unauthorized groups have been granted permissions to modify memory controller or hardware configuration settings.
-
Audit local user privilegesOn Windows, run 'net user' and 'net localgroup administrators' to list all users with administrative privileges. On Linux, check '/etc/passwd' for users in 'sudo' or 'wheel' groups, and run 'who' to see currently logged in users.Affected if There are multiple local users with administrative or elevated privileges beyond what is strictly required, increasing the attack surface for a privileged local user to exploit this flaw.
-
Check for memory controller utility logsOn Windows, examine Event Viewer -> Windows Logs -> System for entries related to memory controller, IMC, or hardware configuration changes. On Linux, check '/var/log/syslog' or 'dmesg' for memory controller configuration events. Look for unauthorized or unexpected memory settings modifications.Affected if There are log entries showing memory controller configuration changes made by users other than designated administrators, or changes occurring outside of expected maintenance windows.
A system is affected if it runs an Intel Xeon 6 processor with E-cores and has memory controller configurations accessible to privileged local users beyond what is strictly necessary, allowing potential privilege escalation.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataApply Intel-provided firmware/BIOS updates for Xeon 6 processors with E-cores once available. Review and restrict local administrative access to systems running affected processors.
- Consultation8.0 h
- Implementation16.0 h
- Testing12.0 h
- Review / QA4.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $11,200.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-20100 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-20100 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data