CWE-311Weakness · CWE-311

CVE-2025-24008

MEDIUM · 6.5 CVSS v3.1 Published 2025-05-13
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
72/100
Remediation priority · Elevated
Remotely reachable No privileges

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A vulnerability has been identified in SIRIUS 3RK3 Modular Safety System (MSS) (All versions), SIRIUS Safety Relays 3SK2 (All versions). The affected devices do not encrypt data in transit. An attacker with network access could eavesdrop the connection and retrieve sensitive information, including obfuscated safety passwords.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

The SIRIUS 3RK3 Modular Safety System and SIRIUS Safety Relays 3SK2 transmit data in cleartext without encryption. An attacker with network access can perform eavesdropping to capture sensitive information including obfuscated safety passwords, leading to confidentiality breach.

MitigationImplement network segmentation and use VPN tunnels to protect traffic to/from affected devices. Contact Siemens for firmware updates that add encryption capabilities.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
None
Availability
None

CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify SIRIUS 3RK3 or 3SK2 devices on the network
    Review network inventory, PLC programs, or engineering station configurations for presence of Siemens SIRIUS 3RK3 Modular Safety System or SIRIUS Safety Relays 3SK2. Check device labels, IP address assignments, or use network scanning tools that can identify these device types.
    Affected if Either product family is present in the environment
  2. Determine the device firmware version
    Access the device via its web interface, Siemens engineering software (such as TIA Portal), or console connection, and navigate to the firmware information or device status section. Record the installed firmware version.
    Affected if The installed firmware version falls within any affected range or is an older version prior to when encryption was added
  3. Verify if network encryption is enabled
    Within the device configuration settings, locate the network security or communication settings. Check whether any encryption, TLS, or secure communication options are available and enabled for data transmission.
    Affected if Encryption settings are disabled, set to 'none', or the device lacks encryption options for its network communications
  4. Capture and inspect network traffic
    Use a network packet capture tool (such as Wireshark) on the same network segment as the affected devices. Capture traffic to and from the SIRIUS devices and examine the protocol contents. Look for plaintext transmission of configuration data, passwords, or safety parameters.
    Affected if Network captures show unencrypted data being transmitted, including any obfuscated passwords visible in cleartext in the packet contents

You are affected if SIRIUS 3RK3 or 3SK2 devices are present and transmit data over the network without encryption enabled, allowing potential eavesdropping of sensitive safety parameters.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Implement network segmentation and use VPN tunnels to protect traffic to/from affected devices. Contact Siemens for firmware updates that add encryption capabilities.

Have this fixed Scoped from the published advisory
  • Consultation8.0 h
  • Implementation24.0 h
  • Testing12.0 h
  • Review / QA6.0 h
50.0 hours of engineering $8,800
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $14,080.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2025-24008 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2025-24008 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data