CVE-2025-24332
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedNokia Single RAN AirScale baseband allows an authenticated administrative user access to all physical boards after performing a single login to the baseband system board. The baseband does not re-authenticate the user when they connect from the baseband system board to the baseband capacity boards using the internal bsoc SSH service, which is available only internally within the baseband and through the internal backplane between the boards. The bsoc SSH allows login from one board to another via the baseband internal backplane using an SSH private key present on the baseband system board. This bsoc SSH capability was previously considered an administrative functionality but has now been restricted to be available only to baseband root-privileged administrators. This restriction mitigates the possibility of misuse with lower-level privileges (e.g., from baseband software images). This mitigation is included starting from release 23R4-SR 3.0 MP and later
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceNokia Single RAN AirScale baseband allows authenticated admin users to access all physical boards after a single login. The internal bsoc SSH service, which connects boards via the backplane using SSH private keys, does not re-authenticate users when moving between the system board and capacity boards. This allows lateral movement across boards without additional authentication.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Adjacent
- Complexity
- High
- Privileges
- Low
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify the installed Nokia Single RAN AirScale release versionUse the Nokia OSS or CLI to retrieve the baseband software version. Common methods include checking the system information via the OSS management interface or running a version display command on the baseband unit.Affected if The installed version is prior to 23R4-SR 3.0 MP (the patched release).
-
Verify the bsoc SSH service configurationExamine the bsoc service settings on the baseband system. This typically involves accessing the system board's administrative interface and checking the SSH service configuration for the bsoc daemon.Affected if The bsoc SSH service is accessible to non-root administrative users or allows unauthenticated board-to-board movement.
-
Test lateral movement between system board and capacity boardsAs an authenticated non-root admin user, attempt to SSH from the system board to a capacity board using the bsoc service without re-entering credentials. Document whether the connection succeeds without additional authentication.Affected if Non-root admin users can move between boards via bsoc SSH without re-authentication.
-
Confirm whether access control restrictions are enforcedCheck if the system restricts bsoc SSH access to root-privileged administrators only. This may involve reviewing user privilege levels and access control lists on the baseband unit.Affected if The system allows non-root admin users to access bsoc SSH service, indicating the access control restriction is not properly enforced.
A user is affected if their Nokia Single RAN AirScale version is before 23R4-SR 3.0 MP and non-root admin accounts can access capacity boards via the bsoc SSH service without re-authentication.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
dbcve · scopedUpgrade to release 23R4-SR 3.0 MP or later, which restricts bsoc SSH access to only root-privileged administrators. Verify that the access control restriction is properly enforced.
23R4-SR 3.0 MP or later
- 1. Identify the current software version running on the Nokia Single RAN AirScale baseband system
- 2. If the current version is earlier than 23R4-SR 3.0 MP, plan and schedule an upgrade to release 23R4-SR 3.0 MP or later
- 3. Perform the upgrade following Nokia's standard upgrade procedures for Single RAN AirScale baseband
- 4. After upgrade, verify that the bsoc SSH service is now restricted to baseband root-privileged administrators only
- 5. Confirm that administrative users with non-root privileges can no longer access capacity boards via the internal bsoc SSH service
Generated from the published advisory — verify against the referenced sources before acting.
- Consultation4.0 h
- Implementation8.0 h
- Testing4.0 h
- Review / QA2.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,120.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-24332 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-24332 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm