Unrestricted File UploadWeakness · CWE-434

CVE-2025-24505

HIGH · 8.8 CVSS v4.0 Published 2025-01-30
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
90/100
Remediation priority · Urgent
Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
This vulnerability allows a high-privileged authenticated PAM user to achieve remote command execution on the affected PAM system by uploading a specially crafted upgrade file.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

A file upload vulnerability in a PAM (Privileged Access Management) system allows high-privileged authenticated users to achieve remote command execution by uploading specially crafted upgrade files. The upgrade mechanism insufficiently validates the uploaded file, permitting arbitrary code execution in the context of the PAM system.

MitigationRestrict upgrade file uploads to only verified, signed packages from trusted sources, implement strict file type validation and content inspection, and run upgrade processing in an isolated sandbox environment.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Adjacent
Complexity
High
Privileges
High
Authentication
X
User interaction
None
Scope
X

CVSS:4.0/AV:A/AC:H/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify PAM system in use
    Inventory your environment for Privileged Access Management (PAM) software installations. Check for common PAM products by reviewing installed software lists, service processes, or web applications running on typical ports (e.g., 443, 8443). Look for PAM-related service names or process executables.
    Affected if A PAM system is present and has an upgrade/upload feature enabled
  2. Locate upgrade or file upload functionality
    Examine the PAM system administrative interface for upgrade, patch, or file upload features. Check the web application URL paths for common upgrade endpoints (e.g., /upgrade, /upload, /patch, /update). Review system documentation or UI navigation for 'System Upgrade', 'Software Update', or 'Plugin Upload' sections.
    Affected if The upgrade/upload feature exists and is accessible to high-privileged users
  3. Verify high-privileged user access
    Review PAM system role definitions and confirm which user roles possess 'Administrator', 'Super Admin', or 'Upgrade' permissions. Check if standard privileged users (non-root, non-owner accounts) can access upgrade or upload features.
    Affected if High-privileged authenticated users can access the upgrade/upload functionality
  4. Inspect file validation configuration
    Access PAM system configuration files or admin settings related to file uploads. Look for parameters controlling file type validation, signature verification, content inspection, or sandboxing. Common config locations: config.xml, upload.conf, security.json, or admin GUI settings panels.
    Affected if File validation is disabled, weak (e.g., only extension-based), or absent in the upgrade configuration
  5. Check for unauthorized upgrade files
    Review the PAM system directories where upgrade files are stored or processed. Look for unexpected .zip, .tar, .jar, or executable files in upgrade staging folders, temp directories, or web root. Compare against known legitimate upgrade packages.
    Affected if Unexpected or unsigned upgrade files exist in the system or upload directories

You are affected if a PAM system with an upgrade/upload feature is present, high-privileged users can access it, and file validation is weak or absent.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Restrict upgrade file uploads to only verified, signed packages from trusted sources, implement strict file type validation and content inspection, and run upgrade processing in an isolated sandbox environment.

Have this fixed Scoped from the published advisory
  • Consultation4.0 h
  • Implementation16.0 h
  • Testing8.0 h
  • Review / QA4.0 h
32.0 hours of engineering $5,600
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $8,960.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2025-24505 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2025-24505 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data