CVE-2025-25067
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedmySCADA myPRO Manager is vulnerable to an OS command injection which could allow a remote attacker to execute arbitrary OS commands.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · low confidencemySCADA myPRO Manager contains an OS command injection vulnerability that allows remote attackers to execute arbitrary operating system commands, likely through unsanitized user input being passed to system shell calls.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data< 1.4CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify myPRO Manager versionLocate and inspect the installed mySCADA myPRO Manager version information, typically found in the application properties, about dialog, or installation directory metadataAffected if The installed version number is less than 1.4 (e.g., 1.3.x, 1.2.x, etc.)
-
Verify manager interface statusCheck whether the myPRO Manager web interface or management service is currently running and enabled on the systemAffected if The manager interface service is active and listening on network ports
-
Assess network exposureReview firewall rules, network bindings, and access controls to determine if the manager interface is accessible from network segments beyond localhostAffected if The manager interface is bound to non-loopback addresses or accessible from external network segments
-
Inspect command execution configurationExamine configuration files or application settings that control how user inputs are processed through system shell callsAffected if The application is configured to pass user-supplied input directly to shell execution functions without validation layers
You are affected if mySCADA myPRO Manager version is below 1.4 AND the manager interface is accessible, as the command injection vulnerability requires both conditions to be exploitable.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
dbcve · scoped1.4
Apply vendor patches when available; if no patch exists, implement strict input validation, use parameterized command execution instead of shell commands, and restrict network access to the management interface.
mySCADA myPRO version 1.4 or later
- 1. Identify the current version of mySCADA myPRO Manager installed in your environment
- 2. Download mySCADA myPRO version 1.4 or later from the official vendor website (www.myscada.org)
- 3. Review the official mySCADA upgrade documentation for version 1.4
- 4. Apply the upgrade following vendor-provided upgrade procedures
- 5. After upgrade, verify the new version is 1.4 or later
- 6. Confirm the OS command injection vulnerability is resolved by testing or consulting vendor release notes
Generated from the published advisory — verify against the referenced sources before acting.
- Consultation8.0 h
- Implementation16.0 h
- Testing8.0 h
- Review / QA4.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $10,240.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-25067 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-25067 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data