NVD · uneditedTenda AC10 V1.0 V15.03.06.23 is vulnerable to Buffer Overflow in form_fast_setting_wifi_set via the parameter ssid.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceA buffer overflow vulnerability exists in the Tenda AC10 V1.0 router firmware V15.03.06.23 within the form_fast_setting_wifi_set function. The vulnerability is triggered through the ssid parameter, allowing an attacker to overflow a buffer and potentially achieve remote code execution on the device.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data= 15.03.06.23CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify device modelCheck the router label or log into the web admin interface and navigate to System Status or Device Info to confirm the model is Tenda AC10 V1.0Affected if Device is not a Tenda AC10 V1.0 router - this vulnerability does not apply
-
Check firmware versionIn the web admin interface, go to System Settings > Firmware Upgrade or System Status page and note the firmware version displayedAffected if Firmware version is exactly 15.03.06.23 - this specific version is affected
-
Verify web interface accessibilityAttempt to access the router web admin interface from a browser using the router IP address (typically 192.168.0.1 or 192.168.1.1)Affected if Web interface is accessible over untrusted networks (WAN) - the vulnerable form_fast_setting_wifi_set function is exposed
-
Confirm remote management statusIn the web admin interface, go to Advanced Settings > Remote Management or similar section and check if remote web management is enabledAffected if Remote management is enabled and the web interface is WAN-accessible - attacker can reach the vulnerable ssid parameter
A user is affected if they have a Tenda AC10 V1.0 router running firmware version 15.03.06.23 with the web admin interface accessible from untrusted networks.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataApply the vendor-provided firmware patch when available. Until then, restrict administrative web interface access to trusted networks and monitor for indicators of compromise.
- Consultation4.0 h
- Implementation2.0 h
- Testing6.0 h
- Review / QA3.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $4,160.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-25674 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-25674 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data