CVE-2025-2697
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedIBM Cognos Command Center 10.2.4.1 and 10.2.5 could allow a remote attacker to conduct phishing attacks, using an open redirect attack. By persuading a victim to visit a specially crafted Web site, a remote attacker could exploit this vulnerability to spoof the URL displayed to redirect a user to a malicious Web site that would appear to be trusted. This could allow the attacker to obtain highly sensitive information or conduct further attacks against the victim.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceIBM Cognos Command Center versions 10.2.4.1 and 10.2.5 contain an open redirect vulnerability that allows remote attackers to craft malicious URLs appearing to originate from the trusted IBM domain. By tricking users into visiting specially crafted links, attackers can redirect victims to arbitrary malicious websites to conduct phishing attacks or steal sensitive credentials.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data= 10.2.4.1= 10.2.5CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- User interaction
- Required
- Scope
- Changed
- Confidentiality
- High
- Integrity
- High
- Availability
- None
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:N
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Verify IBM Cognos Command Center is installedLocate the IBM Cognos Command Center installation directory or check for the service running on your serverAffected if The product is not installed on the system
-
Identify the installed versionCheck the version of IBM Cognos Command Center installed. This is typically found in the product documentation, installation logs, or through the administration interface under About or System InformationAffected if The installed version is exactly 10.2.4.1 or exactly 10.2.5
-
Confirm the web interface is accessibleDetermine if the IBM Cognos Command Center web interface is exposed and accessible to users or attackersAffected if The web interface is accessible without additional authentication controls
-
Review redirect handling in web configurationInspect the web application configuration files or proxy settings for URL redirect or forwarding functionality that could be exploitedAffected if Redirect parameters exist and are not properly validated against a whitelist of allowed domains
A system is affected if IBM Cognos Command Center version 10.2.4.1 or 10.2.5 is installed and its web interface with redirect functionality is accessible.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataApply vendor patches when available; implement URL validation to ensure redirect targets are within expected domains; users should hover over links to verify destination URLs before clicking.
- Consultation3.0 h
- Implementation4.0 h
- Testing3.0 h
- Review / QA2.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $3,408.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-2697 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-2697 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm