The Linux deprivileged user vpuser in Radiflow iSAP Smart Collector (CentOS 7 - VSAP 1.20) can read the entire file system content, including files belonging to other users and having restricted access (like, for example, the root password hash).

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

The Linux deprivileged user 'vpuser' in Radiflow iSAP Smart Collector (CentOS 7, VSAP 1.20) has excessive file system read permissions, allowing unauthorized access to sensitive files including other users' files and restricted system files like the root password hash.

MitigationRestrict vpuser account file system access to only necessary directories using appropriate file permissions and access controls; ensure sensitive files (especially /etc/shadow and configuration files with credentials) are not readable by this deprivileged user account.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
High
User interaction
None
Scope
Changed
Confidentiality
High
Integrity
None
Availability
None

CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Verify vpuser account exists
    Run 'id vpuser' or 'grep ^vpuser /etc/passwd' to confirm the vpuser account is present on the system
    Affected if vpuser account exists on the system (this is the prerequisite for being vulnerable)
  2. Check Radiflow iSAP Smart Collector version
    Run 'rpm -q vsap' or look for version files in /opt/radiflow or /opt/vsap directories. Compare the installed version to VSAP 1.20
    Affected if Installed VSAP version is 1.20 or falls within the affected version range (if additional ranges were provided)
  3. Test vpuser access to /etc/shadow
    As the vpuser (using 'su - vpuser' or 'sudo -u vpuser'), attempt to read the shadow file with 'cat /etc/shadow'
    Affected if vpuser can successfully read /etc/shadow and view password hashes (indicates excessive permissions)
  4. Verify vpuser can access other users home directories
    As vpuser, attempt to list and read files in other users home directories (e.g., 'ls /home/otheruser', 'cat /home/otheruser/.bashrc')
    Affected if vpuser can read files in other users home directories without proper authorization
  5. Check sensitive file permissions accessible by vpuser
    As vpuser, attempt to access configuration files with credentials, SSH keys, or other sensitive data in system directories
    Affected if vpuser can read files containing credentials, API keys, or other sensitive configuration data

If the vpuser account exists and can read /etc/shadow or access other restricted files, the environment is affected by this CVE.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Restrict vpuser account file system access to only necessary directories using appropriate file permissions and access controls; ensure sensitive files (especially /etc/shadow and configuration files with credentials) are not readable by this deprivileged user account.

Have this fixed Scoped from the published advisory
  • Consultation4.0 h
  • Implementation8.0 h
  • Testing4.0 h
  • Review / QA2.0 h
18.0 hours of engineering $3,200
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,120.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2025-27028 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2025-27028 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data