Improper Input ValidationWeakness · CWE-20

CVE-2025-27537

MEDIUM · 5.5 CVSS v3.1 Published 2025-08-12
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
57/100
Remediation priority · Elevated
Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Improper input validation for some Edge Orchestrator software before version 24.11.1 for Intel(R) Tiber(TM) Edge Platform may allow an authenticated user to potentially enable escalation of privilege via adjacent access.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

Improper input validation in Intel Tiber Edge Platform's Edge Orchestrator software before version 24.11.1 allows an authenticated user with adjacent network access to potentially escalate privileges. The vulnerability stems from insufficient validation of input data that could be manipulated to gain elevated access rights.

MitigationUpgrade Edge Orchestrator software to version 24.11.1 or later to remediate this vulnerability. Review access controls and monitor for suspicious privilege escalation attempts in the interim.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Adjacent
Complexity
Low
Privileges
Low
User interaction
None
Scope
Unchanged
Confidentiality
Low
Integrity
Low
Availability
Low

CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Locate Edge Orchestrator installation
    Search for Intel Edge Orchestrator executables or service. Common locations: /opt/intel/edge-orchestrator, C:\Program Files\Intel\Edge Orchestrator, or check system services. Run: systemctl list-units --all | grep -i orchestrator or sc query IntelEdgeOrchestrator
    Affected if The software is installed on the system
  2. Determine installed version
    Check version of the Edge Orchestrator service or executable. Run: orchestrator --version, or check the service properties, or inspect version info in the binary, or look for a version file in the installation directory
    Affected if Version is lower than 24.11.1 or cannot be determined (treat as vulnerable)
  3. Verify service is running
    Check if Edge Orchestrator service is active. Run: systemctl is-active orchestrator or sc query IntelEdgeOrchestrator state
    Affected if Service is running and accepts network connections from adjacent networks
  4. Check authentication configuration
    Review authentication and authorization configuration files in the Edge Orchestrator config directory. Look for settings related to user permissions, role-based access, or input validation rules
    Affected if Adjacent network users can authenticate to the system (default or misconfigured authentication)

System is affected if Intel Tiber Edge Platform Edge Orchestrator software is installed with a version lower than 24.11.1, the service is running, and adjacent network users can authenticate to it.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Upgrade Edge Orchestrator software to version 24.11.1 or later to remediate this vulnerability. Review access controls and monitor for suspicious privilege escalation attempts in the interim.

Recommended fix High confidence

24.11.1 for Intel(R) Tiber(TM) Edge Platform

  1. 1. Identify the current version of Intel(R) Tiber(TM) Edge Platform Edge Orchestrator software installed in your environment
  2. 2. Navigate to Intel's official support website or Intel Download Center
  3. 3. Locate and download Intel Edge Orchestrator software version 24.11.1 or later
  4. 4. Review Intel's upgrade documentation for the Tiber Edge Platform
  5. 5. Perform a backup of current configuration data before initiating the upgrade
  6. 6. Apply the upgrade following Intel's standard installation procedures
  7. 7. Verify the installed version is 24.11.1 or later after completion
  8. 8. Test that the Edge Orchestrator functionality operates normally post-upgrade

Generated from the published advisory — verify against the referenced sources before acting.

Have this fixed Scoped from the published advisory
  • Consultation4.0 h
  • Implementation8.0 h
  • Testing6.0 h
  • Review / QA4.0 h
22.0 hours of engineering $3,860
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $6,176.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2025-27537 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2025-27537 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data