CVE-2025-27575
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedAn unauthenticated attacker can obtain EV charger version and firmware upgrading history by knowing the charger ID.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceAn unauthenticated attacker can retrieve EV charger version and firmware upgrade history by knowing or enumerating the charger ID, without any authentication required. This exposes sensitive firmware version information that could facilitate targeted attacks against specific vulnerable charger models.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data<= 3.6.0CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- Low
- Integrity
- None
- Availability
- None
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify Growatt Cloud Portal installationSearch for Growatt Cloud Portal in your environment's software inventory or check for web services running on ports commonly used by this portalAffected if Growatt Cloud Portal is present and accessible on the network
-
Determine installed version of Growatt Cloud PortalCheck the application version through its web interface (typically found in About/Help section, or in server logs/package metadata)Affected if Version is 3.6.0 or lower (the vulnerability affects versions up to and including 3.6.0)
-
Verify API endpoint accessibilityAttempt to access the charger API endpoint (typically /api/charger or similar endpoint paths that return charger data) without providing any authentication credentialsAffected if The endpoint responds with data (charger version/firmware history) without requiring login or token authentication
-
Check for charger ID exposureSend a request with an enumerated or known charger ID to the API endpoint without authentication and observe if firmware version and upgrade history are returned in the responseAffected if Sensitive firmware version and upgrade history information is returned without any authentication requirement
If Growatt Cloud Portal version 3.6.0 or lower is running and the charger API endpoint returns version/firmware data without requiring authentication, the environment is affected by this CVE.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataImplement proper authentication and authorization checks on the charger API endpoint. Add rate limiting and input validation to prevent charger ID enumeration.
- Consultation6.0 h
- Implementation12.0 h
- Testing6.0 h
- Review / QA3.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $7,680.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-27575 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-27575 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm