CVE-2025-27640
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedVasion Print (formerly PrinterLogic) before Virtual Appliance Host 22.0.1002 Application 20.0.2614 allows SQL Injection V-2024-012.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceSQL Injection vulnerability in Vasion Print (formerly PrinterLogic) allows unauthenticated attackers to inject malicious SQL queries through insufficiently validated input fields in the web application. The vulnerability exists in both the Virtual Appliance Host and Application components prior to versions 22.0.1002 and 20.0.2614 respectively.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data< 20.0.2614< 22.0.1002CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify Virtual Appliance Host versionAccess the Virtual Appliance admin interface and navigate to System Settings > About, or run 'plc -v' via SSH console to retrieve the host versionAffected if Version is below 22.0.1002
-
Identify Application component versionLog into the Vasion Print admin panel and navigate to Help > About, or check the version displayed on the web login page footerAffected if Version is below 20.0.2614
-
Confirm web application exposureDetermine if the Vasion Print web interface is accessible over HTTP/HTTPS from network locations outside the trusted internal networkAffected if Web interface is exposed to untrusted networks or the internet
-
Inspect input handlingReview web application logs for unusual SQL syntax in request parameters, particularly in unauthenticated endpoints like login forms or search fieldsAffected if Input fields lack proper SQL parameterization and are publicly accessible
Environment is affected if either the Virtual Appliance Host version is below 22.0.1002 or the Application version is below 20.0.2614, and the web interface accepts unauthenticated input.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
dbcve · scoped20.0.261422.0.1002
Upgrade Vasion Print Virtual Appliance Host to version 22.0.1002 or later AND Application to version 20.0.2614 or later. If immediate patching is not feasible, implement web application firewall (WAF) rules to detect and block SQL injection payloads.
Vasion Print Application 20.0.2614 or higher / Virtual Appliance Host 22.0.1002 or higher
- 1. Back up the current Vasion Print database and configuration before starting the upgrade.
- 2. Log in to the Vasion Print admin console or access the Virtual Appliance management interface.
- 3. Download the updated Virtual Appliance Host version 22.0.1002 or later from the Vasion/PrinterLogic customer portal.
- 4. Deploy the new Virtual Appliance image following the vendor's deployment documentation (help.printerlogic.com).
- 5. Apply the Vasion Print Application update to version 20.0.2614 or later.
- 6. Verify the installed versions match the patched releases (Application: 20.0.2614+, Appliance Host: 22.0.1002+).
- 7. Test core functionality to confirm the SQL injection vulnerability is resolved and the application operates normally.
Generated from the published advisory — verify against the referenced sources before acting.
- Consultation4.0 h
- Implementation8.0 h
- Testing6.0 h
- Review / QA3.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,888.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-27640 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-27640 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data