CVE-2025-29534
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedAn authenticated remote code execution vulnerability in PowerStick Wave Dual-Band Wifi Extender V1.0 allows an attacker with valid credentials to execute arbitrary commands with root privileges. The issue stems from insufficient sanitization of user-supplied input in the /cgi-bin/cgi_vista.cgi executable, which is passed to a system-level function call.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceAn authenticated remote code execution vulnerability exists in the PowerStick Wave Dual-Band Wifi Extender V1.0. The /cgi-bin/cgi_vista.cgi executable fails to properly sanitize user-supplied input before passing it to a system-level function call, allowing an attacker with valid credentials to execute arbitrary commands with root privileges.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- Low
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Confirm device model and firmware versionAccess the device's web administration interface or check the device label/metadata. Look for 'PowerStick Wave Dual-Band Wifi Extender' version 1.0.Affected if The device is a PowerStick Wave Dual-Band Wifi Extender running firmware V1.0
-
Verify CGI endpoint accessibilityAttempt to access the URL path /cgi-bin/cgi_vista.cgi on the device's IP address using a web browser or curl command (e.g., curl http://<device-ip>/cgi-bin/cgi_vista.cgi).Affected if The /cgi-bin/cgi_vista.cgi endpoint responds (even with an error) indicating it exists and is reachable
-
Check device network exposureDetermine if the device management interface is accessible from untrusted networks. Use nmap or check router/firewall rules to see if ports 80/443 on the device are exposed to the internet or guest networks.Affected if The device's web interface is accessible from networks outside the trusted local network
-
Review authentication configurationCheck if the device is using default administrator credentials. Log into the web interface and verify the admin account is not using manufacturer default usernames and passwords.Affected if The device still has default credentials configured or uses weak authentication
-
Check for firmware updatesIn the device's admin interface, look for a Firmware or Software Update section. Note the current firmware version displayed and compare against any available updates.Affected if The firmware version is V1.0 and no newer version is installed
You are affected if you are running a PowerStick Wave Dual-Band Wifi Extender V1.0 with the /cgi-bin/cgi_vista.cgi endpoint accessible and using default or weak authentication credentials.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataRestrict access to the/cgi_vista.cgi endpoint using strong authentication and network segmentation. If a vendor patch becomes available, apply it immediately. Otherwise, consider replacing the device or implementing additional access controls to limit exposure.
- Consultation3.0 h
- Implementation4.0 h
- Testing4.0 h
- Review / QA2.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $3,648.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-29534 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-29534 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data