CVE-2025-30519
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedDover Fueling Solutions ProGauge MagLink LX4 Devices have default root credentials that cannot be changed through standard administrative means. An attacker with network access to the device can gain administrative access to the system.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceDover Fueling Solutions ProGauge MagLink LX4 fuel gauging devices contain static default root credentials that cannot be changed through standard administrative interfaces. An attacker with network access to the device can authenticate using these hardcoded credentials and gain full administrative control.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify the device modelCheck the device label, web interface, or management console for the exact model name and firmware version. Look for 'ProGauge MagLink LX4' or 'Dover Fueling Solutions' branding.Affected if The device is a Dover Fueling Solutions ProGauge MagLink LX4 fuel gauging device and the firmware version falls within the affected range (if known).
-
Verify default credentials are in useAttempt to access the device administrative interface using commonly known default credentials for this device, or check if the device ships with hardcoded root credentials documented in user manuals or security advisories.Affected if The device authenticates with static default credentials that cannot be changed through standard administrative interfaces.
-
Check credential change capabilityLog into the administrative interface and attempt to change the root/administrative password through the settings or user management section. Observe whether the option is missing, disabled, or returns an error.Affected if The administrative interface does not allow changing the root password, or the change is not persisted after reboot.
-
Assess network exposureReview network configuration, firewall rules, and access control lists to determine if the device management interface is accessible from untrusted networks or the internet.Affected if The device administrative interface is accessible from network segments outside the trusted management zone.
A user is affected if they have a Dover Fueling Solutions ProGauge MagLink LX4 device with static default root credentials that cannot be changed via the administrative interface and the device is accessible from the network.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataIsolate the device behind strict network segmentation with firewall rules limiting access to authorized personnel only, and contact the vendor for an official firmware update or credential change procedure.
- Consultation8.0 h
- Implementation12.0 h
- Testing6.0 h
- Review / QA4.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $8,608.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-30519 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-30519 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data