CVE-2025-32866
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedA vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetLogs' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceSQL injection vulnerability in TeleControl Server Basic's 'GetLogs' method allows authenticated remote attackers to bypass authorization, read/write to the database, and execute code with NT AUTHORITY\NetworkService privileges. Affected versions are all versions prior to V3.1.2.2, requiring access to port 8000.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data< 3.1.2.2CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- Low
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify TeleControl Server Basic installationCheck system for Siemens TeleControl Server Basic software installation by reviewing installed programs, services, or common installation directories.Affected if The software is not installed, the vulnerability does not apply.
-
Check installed version against affected rangeLocate the installed version of TeleControl Server Basic (typically available in program properties, service information, or version file) and compare it to the affected range: versions prior to 3.1.2.2.Affected if The installed version is lower than 3.1.2.2.
-
Verify port 8000 is exposedCheck if port 8000 is listening on the system (using netstat, PowerShell Get-NetTcpConnection, or similar network scanning tools).Affected if Port 8000 is open and accepting connections, creating the attack surface for the vulnerability.
-
Confirm GetLogs method accessibilityIf port 8000 is open, verify the TeleControl Server Basic web service is accessible by attempting to reach the GetLogs endpoint (e.g., via HTTP request to the service endpoint on port 8000).Affected if The GetLogs method is exposed and accessible on port 8000.
A system is affected if TeleControl Server Basic version is below 3.1.2.2 and the service on port 8000 with the GetLogs method is accessible on the network.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
dbcve · scoped3.1.2.2
Upgrade to TeleControl Server Basic version V3.1.2.2 or later to remediate the SQL injection vulnerability.
TeleControl Server Basic V3.1.2.2
- Identify the current installed version of TeleControl Server Basic
- Backup the current installation and database before proceeding
- Navigate to Siemens CERT portal (cert-portal.siemens.com) or official Siemens support to obtain version 3.1.2.2
- Download the update package for TeleControl Server Basic V3.1.2.2
- Stop the TeleControl Server Basic service before applying the update
- Apply the upgrade to version 3.1.2.2 following Siemens installation documentation
- Restart the TeleControl Server Basic service
- Verify the installation was successful by checking the version number
Generated from the published advisory — verify against the referenced sources before acting.
- Consultation2.0 h
- Implementation3.0 h
- Testing2.0 h
- Review / QA1.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $2,272.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-32866 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-32866 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data