Telecontrol Server BasicApplication · Siemens

CVE-2025-32867

HIGH · 8.8 CVSS v3.1 Published 2025-04-16
Fix available
A fix is available. Upgrade to 3.1.2.2 or later.
See remediation →
94/100
Remediation priority · Urgent
Remotely reachable Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'CreateBackup' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

TeleControl Server Basic versions before V3.1.2.2 contain an SQL injection vulnerability in the 'CreateBackup' method. An authenticated remote attacker who can reach port 8000 can exploit this to bypass authorization, read/write to the database, and execute code with NT AUTHORITY\NetworkService privileges.

MitigationUpgrade TeleControl Server Basic to version V3.1.2.2 or later to remediate the SQL injection vulnerability. Restrict network access to port 8000 as a compensating control until the upgrade is applied.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Telecontrol Server BasicApplication
Affected:< 3.1.2.2

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
Low
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Confirm TeleControl Server Basic installation
    Locate the TeleControl Server Basic installation directory or check installed programs list to identify if the product is present on the system
    Affected if The product is installed and running on the target system
  2. Identify installed version
    Use the product's built-in version information feature, check the About dialog, or inspect version metadata in the installation directory to determine the exact version number
    Affected if The installed version is lower than 3.1.2.2 (e.g., 3.1.2.1, 3.1.0.x, or earlier)
  3. Verify port 8000 accessibility
    Check if port 8000 is listening and accessible from network locations using tools such as netstat, telnet, or a port scanner from an external perspective
    Affected if Port 8000 is open and reachable from an untrusted network segment or from attacker-controlled systems
  4. Confirm CreateBackup method exposure
    Determine if the TeleControl Server Basic web service or API is accessible and the CreateBackup method is available as part of the exposed interface
    Affected if The web interface/API on port 8000 is accessible and the CreateBackup functionality is present without additional compensating controls

The environment is affected if TeleControl Server Basic is installed with a version lower than 3.1.2.2 and port 8000 is network-accessible to an attacker.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Upgrade available Upgrade to 3.1.2.2 or later
Fixed in 3.1.2.2
Interim mitigation

Upgrade TeleControl Server Basic to version V3.1.2.2 or later to remediate the SQL injection vulnerability. Restrict network access to port 8000 as a compensating control until the upgrade is applied.

Recommended fix High confidence

TeleControl Server Basic V3.1.2.2

  1. Obtain TeleControl Server Basic version 3.1.2.2 from the official Siemens support portal (cert-portal.siemens.com or Siemens Industry Online Support)
  2. Review the Siemens upgrade documentation for TeleControl Server Basic before proceeding
  3. Back up the current TeleControl Server Basic installation, including configuration files and the database
  4. Test the upgrade in a non-production/staging environment first
  5. Stop the TeleControl Server Basic service before performing the upgrade
  6. Install version 3.1.2.2 following Siemens standard upgrade procedures
  7. Verify the application starts correctly and the CreateBackup method functions properly
  8. Confirm the SQL injection vulnerability is remediated by testing or reviewing release notes
Caveat Review Siemens release notes for this version to check for any configuration or behavioral changes that may affect your deployment

Generated from the published advisory — verify against the referenced sources before acting.

Fix this in Telecontrol Server Basic Scoped from the published advisory
  • Consultation4.0 h
  • Implementation2.0 h
  • Testing4.0 h
  • Review / QA2.0 h
12.0 hours of engineering $2,120
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $3,392.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2025-32867 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2025-32867 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data