CVE-2025-34150
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedThe PPPoE configuration interface of the Shenzhen Aitemi M300 Wi-Fi Repeater (hardware model MT02) is vulnerable to command injection via the 'user' parameter. Input is processed unsafely during network setup, allowing attackers to execute arbitrary system commands with root privileges.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceThe PPPoE configuration interface in the Shenzhen Aitemi M300 Wi-Fi Repeater (MT02) fails to sanitize input in the 'user' parameter during network setup. This allows unauthenticated attackers to inject and execute arbitrary OS commands with root privileges by crafting malicious input in the PPPoE user field.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Adjacent
- Complexity
- Low
- Privileges
- None
- Authentication
- X
- User interaction
- None
- Scope
- X
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Confirm device model is Aitemi M300 (MT02)Check device label, web interface status page, or DHCP client hostname for 'Aitemi M300' or 'MT02'Affected if Device is a Shenzhen Aitemi M300 Wi-Fi Repeater (MT02)
-
Check firmware versionAccess device web interface and navigate to System or Status page to view firmware versionAffected if Firmware version is unpatched (compare to any vendor release notes if available)
-
Locate PPPoE configuration interfaceAccess device web interface and navigate to Network or WAN settings to find PPPoE configuration optionsAffected if PPPoE configuration interface is present on the device
-
Inspect the user parameter in PPPoE settingsView the PPPoE configuration form HTML or intercept the HTTP request when saving settings to examine how the 'user' parameter is handledAffected if The 'user' field accepts input without visible sanitization or validation before being processed
-
Determine network exposure of the device management interfaceCheck router or firewall configurations to see if the device web interface is accessible from WAN or untrusted networksAffected if The PPPoE configuration interface is exposed to the internet or untrusted networks
If you have a Shenzhen Aitemi M300 (MT02) with an accessible PPPoE configuration interface, especially if exposed to untrusted networks, you are likely affected by this command injection vulnerability.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataUntil a vendor patch is available, disable or restrict access to the PPPoE configuration interface. If feasible, implement input validation to reject shell metacharacters in the user parameter, and consider network segmentation to limit exposure of the management interface.
- Consultation3.0 h
- Implementation6.0 h
- Testing4.0 h
- Review / QA2.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $4,224.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-34150 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-34150 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm