CVE-2025-3606
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedVestel AC Charger version 3.75.0 contains a vulnerability that could enable an attacker to access files containing sensitive information, such as credentials which could be used to further compromise the device.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · moderate confidenceVestel AC Charger version 3.75.0 contains an information disclosure vulnerability that allows unauthorized access to files containing sensitive information, including credentials. This file access could enable further compromise of the device.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- None
- Availability
- None
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify the installed firmware versionAccess the Vestel AC Charger administrative interface or check the device system information page to retrieve the current firmware version. This is typically found under Settings, System Info, or About sections of the web management console or mobile app.Affected if The firmware version displayed is exactly 3.75.0
-
Verify network accessibility of the chargerDetermine if the Vestel AC Charger is reachable from untrusted networks by checking its IP address, firewall rules, and network exposure. Attempt to access the device from a network segment that should not have administrative access.Affected if The device is accessible from networks that should not have access (e.g., public internet, untrusted LAN segments)
-
Inspect file system access controlsIf you have administrative access, examine the file system permissions and access control settings on the device. Look for any configuration that allows unauthenticated or unauthorized file retrieval.Affected if File system allows access to sensitive configuration or credential files without proper authentication
-
Check for exposed sensitive filesAttempt to access common file paths that may contain credentials or configuration data (e.g., configuration backups, password files, authentication tokens) using the device web interface or API endpoints.Affected if Sensitive files containing credentials or authentication tokens are accessible without authorization
Your environment is affected if the Vestel AC Charger is running firmware version 3.75.0 and has network accessibility that allows unauthorized file system access to sensitive information.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataUpdate to a patched firmware version if available; otherwise, restrict network access to the charger and implement proper authentication and authorization controls for file system access.
- Consultation4.0 h
- Implementation8.0 h
- Testing6.0 h
- Review / QA4.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $6,176.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-3606 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-3606 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data