CWE-805Weakness · CWE-805

CVE-2025-36461

HIGH · 7.3 CVSS v3.1 Published 2025-11-17
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
73/100
Remediation priority · Elevated

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Multiple out-of-bounds read and write vulnerabilities exist in the ControlVault WBDI Driver Broadcom Storage Adapter functionality of Dell ControlVault3 prior to 5.15.14.19 and Dell ControlVault3 Plus prior to 6.2.36.47. A specially crafted WinBioControlUnit call can lead to memory corruption. An attacker can issue an api call to trigger this vulnerability. This vulnerability is triggered when submitting a `WinBioControlUnit` call to the StorageAdapter with the ControlCode 0 (`WBIO_USH_GET_TEMPLATE`) and with either and an invalid `ReceiveBuferSize` and/or an invalid `SendBufferSize`.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

Out-of-bounds read/write vulnerabilities exist in the Dell ControlVault WBDI Driver's Broadcom Storage Adapter functionality. The vulnerability is triggered when submitting a WinBioControlUnit call with ControlCode 0 (WBIO_USH_GET_TEMPLATE) using invalid ReceiveBufferSize or SendBufferSize parameters, leading to memory corruption.

MitigationApply the vendor-supplied driver updates: Dell ControlVault3 to version 5.15.14.19 or later, and Dell ControlVault3 Plus to version 6.2.36.47 or later.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Local
Complexity
Low
Privileges
Low
User interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify Dell ControlVault WBDI driver presence
    Open Device Manager, expand 'Biometric devices', look for 'Dell ControlVault WBDI' or 'Broadcom Storage Adapter' entries. Alternatively, run 'driverquery /v | findstr -i controlvault' or check registry under HKLM\SYSTEM\CurrentControlSet\Services for WBDI or biometric-related drivers.
    Affected if The driver is not present on the system, the vulnerability does not apply.
  2. Retrieve the installed driver version
    In Device Manager, right-click the Dell ControlVault WBDI driver, select Properties, go to the Driver tab, and note the Driver Version. Or locate the .sys driver file (typically cvwbdix.sys or similar in C:\Windows\System32\drivers) and check its file properties for version info.
    Affected if Unable to determine driver version means cannot assess exposure.
  3. Determine ControlVault model variant
    Check system BIOS/UEFI information or Dell Support Assist for the specific ControlVault model (ControlVault3 vs ControlVault3 Plus). This distinction is critical as they have different fixed version thresholds.
    Affected if Unknown model prevents accurate version comparison against the correct fixed version.
  4. Compare installed version against fixed versions
    For ControlVault3: compare your driver version to 5.15.14.19. For ControlVault3 Plus: compare to 6.2.36.47. Version comparison should use numeric component-by-component evaluation (major.minor.build.revision).
    Affected if Installed version is lower than 5.15.14.19 (ControlVault3) or lower than 6.2.36.47 (ControlVault3 Plus).

The system is affected if the Dell ControlVault WBDI driver is installed with a version below 5.15.14.19 for ControlVault3 or below 6.2.36.47 for ControlVault3 Plus.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Apply the vendor-supplied driver updates: Dell ControlVault3 to version 5.15.14.19 or later, and Dell ControlVault3 Plus to version 6.2.36.47 or later.

Recommended fix High confidence

Dell ControlVault3: 5.15.14.19+ / Dell ControlVault3 Plus: 6.2.36.47+

  1. Identify the Dell ControlVault3 or ControlVault3 Plus version currently installed on the system
  2. Visit Dell's support website (www.dell.com) and locate the ControlVault WBDI Driver or BIOS/firmware update for your specific Dell system model
  3. Download the updated driver/firmware version 5.15.14.19 or later for ControlVault3, or version 6.2.36.47 or later for ControlVault3 Plus
  4. Apply the driver or firmware update following Dell's standard update procedure
  5. Restart the system if required by the update process
  6. Verify the installed version matches the target fixed version

Generated from the published advisory — verify against the referenced sources before acting.

Have this fixed Scoped from the published advisory
  • Consultation2.0 h
  • Implementation1.0 h
  • Testing4.0 h
  • Review / QA2.0 h
9.0 hours of engineering $1,540
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $2,464.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2025-36461 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2025-36461 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data