NVD · uneditedDell PowerProtect Data Domain BoostFS for client of Feature Release versions 7.7.1.0 through 8.5, LTS2025 release version 8.3.1.0 through 8.3.1.20, LTS2024 release versions 7.13.1.0 through 7.13.1.50, contain an insufficiently protected credentials vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to credential exposure. The attacker may be able to use the exposed credentials to access the system with privileges of the compromised account.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceDell PowerProtect Data Domain BoostFS for client contains an insufficiently protected credentials vulnerability in Feature Release versions 7.7.1.0 through 8.5, LTS2025 release 8.3.1.0 through 8.3.1.20, and LTS2024 release 7.13.1.0 through 7.13.1.50. A low-privileged local attacker can exploit this to access improperly protected credentials and gain unauthorized access to the system with the compromised account's privileges.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data>= 7.7.1.0, < 7.13.1.60>= 7.14.0.0, < 8.3.1.30>= 8.4.0.0, < 8.6.0.0CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Local
- Complexity
- Low
- Privileges
- Low
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Check Data Domain OS versionRun 'ddboost version' or 'system show version' on the Data Domain CLI to retrieve the installed OS versionAffected if The installed version is 7.7.1.0 through 7.13.1.59, or 7.14.0.0 through 8.3.1.29, or 8.4.0.0 through 8.5.x, or 8.6.0.0 (any version below 7.13.1.60, 8.3.1.30, or 8.6.0.0 depending on branch)
-
Confirm BoostFS module is in useCheck if BoostFS is configured by running 'ddboost fs show' or inspecting /ddboost/config for BoostFS-related configuration filesAffected if BoostFS is enabled and the Data Domain OS version falls within the affected ranges
-
Inspect credential storage filesExamine /ddboost/credentials/ or /ddboost/etc/ directories for any world-readable or improperly permissioned credential files. Use 'ls -la' to check file permissionsAffected if Any credential-related files exist with permissions allowing read access by non-root or non-privileged users (e.g., mode 644 or 666)
-
Verify file ownership and permissionsRun 'ls -la /ddboost/' and check if credential or config files are owned by non-privileged users or have overly permissive access rightsAffected if Files in the BoostFS directories are owned by service accounts or have mode bits that permit unauthorized local users to read sensitive data
A user is affected if their Data Domain OS version is within 7.7.1.0 to 7.13.1.59, 7.14.0.0 to 8.3.1.29, or 8.4.0.0 to 8.5.x and BoostFS credential files have overly permissive permissions.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
dbcve · scoped7.13.1.608.3.1.308.6.0.0
Apply vendor-provided security patches for the affected PowerProtect Data Domain BoostFS versions. Rotate any credentials that may have been exposed and investigate the system for signs of compromise. Restrict local access to minimize attack surface until patches are applied.
Upgrade to Data Domain OS 8.6.0.0 or later (or to the latest available version for your LTS track)
- 1. Identify the current Data Domain Operating System version by running 'system show version' or checking the management console
- 2. If running a Feature Release version (7.7.1.0-8.5), upgrade to version 8.6.0.0 or later
- 3. If running LTS2025 (8.3.1.0-8.3.1.20), upgrade to version 8.3.1.30 or later
- 4. If running LTS2024 (7.13.1.0-7.13.1.50), upgrade to version 7.13.1.60 or later
- 5. Download the appropriate update from www.dell.com/support and follow Dell's standard upgrade procedures
- 6. After upgrade, verify the new version is running with 'system show version'
- 7. Review audit logs for any suspicious activity that may have occurred using exposed credentials
Generated from the published advisory — verify against the referenced sources before acting.
- Consultation4.0 h
- Implementation8.0 h
- Testing4.0 h
- Review / QA2.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,120.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-36568 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-36568 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data