Cross-site Scripting (XSS)Weakness · CWE-79

CVE-2025-3905

MEDIUM · 5.4 CVSS v3.1 Published 2025-06-10
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
58/100
Remediation priority · Elevated
Remotely reachable

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists impacting PLC system variables that could cause an unvalidated data injected by authenticated malicious user leading to modify or read data in a victim’s browser.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

A stored XSS (CWE-79) vulnerability exists in PLC system variables where authenticated malicious users can inject unvalidated data into web page generation. When other users access these variables through the PLC web interface, the injected malicious scripts execute in their browsers, potentially allowing attackers to steal session cookies, modify displayed data, or perform actions on behalf of victims.

MitigationImplement robust input validation and output encoding/escaping for all PLC system variables before rendering in the web interface. Apply context-aware sanitization and consider implementing Content Security Policy headers.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
Low
User interaction
Required
Scope
Changed
Confidentiality
Low
Integrity
Low
Availability
None

CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify the PLC system and version
    Locate the PLC device model number and firmware/software version through the device documentation, web interface banner, or system information page. Compare against any available version information from the vendor.
    Affected if The PLC system has a web interface and the version is known to be affected by CVE-2025-3905.
  2. Verify the web interface is enabled
    Check the PLC configuration settings, typically found in the device network or security settings menu, to confirm whether the HTTP/HTTPS web interface is currently active.
    Affected if The web interface is enabled and accessible, providing the attack surface for the XSS.
  3. Inspect PLC system variables for unexpected content
    Access the PLC system variable list through the web interface or engineering software. Review each system variable (such as device name, description, or diagnostic fields) for any HTML, JavaScript, or script-like tags that do not belong to normal system operation.
    Affected if Any PLC system variable contains script tags, event handlers, or suspicious encoded content that was not authored by administrators.
  4. Review user access logs for variable modifications
    Examine PLC audit logs, access logs, or change history for entries showing recent modifications to system variables, especially from user accounts with standard or limited privileges.
    Affected if There are logged changes to system variables made by users who should not normally have that capability, or changes containing unusual character sequences.
  5. Check browser session behavior
    Use a separate browser to access the PLC web interface and navigate to system variable pages. Observe whether unexpected script execution occurs, unusual popups appear, or console errors are generated.
    Affected if JavaScript executes in the browser when viewing system variable pages without directly interacting with input fields.

A user is affected if they run a PLC system with an enabled web interface where other users can inject and store malicious scripts into system variables that are then rendered to anyone viewing those variables.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Implement robust input validation and output encoding/escaping for all PLC system variables before rendering in the web interface. Apply context-aware sanitization and consider implementing Content Security Policy headers.

Have this fixed Scoped from the published advisory
  • Consultation3.0 h
  • Implementation8.0 h
  • Testing4.0 h
  • Review / QA2.0 h
17.0 hours of engineering $3,000
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $4,800.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2025-3905 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2025-3905 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data