CVE-2025-40946
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedA vulnerability has been identified in blueplanet 100 NX3 M8 (All versions), blueplanet 100 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 105 TL3 (All versions < V3.92), blueplanet 105 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 110 TL3 (All versions < V3.92), blueplanet 125 NX3 M10 (All versions), blueplanet 125 TL3 (All versions < V3.92), blueplanet 125 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 137 TL3 (All versions < V3.92), blueplanet 150 TL3 (All versions < V3.92), blueplanet 150 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 155 TL3 (All versions < V3.92), blueplanet 155 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 165 TL3 (All versions < V3.92), blueplanet 165 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 3.0 TL3-60.0 TL3 (All versions), blueplanet 87.0 TL3 (All versions < V3.92), blueplanet 87.0 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 92.0 TL3 (All versions < V3.92), blueplanet 92.0 TL3 GEN2 (All versions < V6.1.4.9), blueplanet gridsave 110 TL3-S (All versions < V3.91), blueplanet gridsave 137 TL3-S (All versions < V3.91), blueplanet gridsave 92.0 TL3-S (All versions < V3.91). A CRC16-based algorithm for generating Technical Service credentials could allow an attacker to derive the credentials from the devices serial number and misuse them to gain unauthorized access.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceThe vulnerability stems from using CRC16, a simple error-detection checksum algorithm, to generate Technical Service credentials for blueplanet solar/grid inverters. Because CRC16 is trivially reversible and provides no cryptographic security, an attacker can derive valid credentials offline by knowing only the device's serial number, which may be obtainable through reconnaissance or physical inspection.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Adjacent
- Complexity
- Low
- Privileges
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- Low
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify the device modelLocate the device nameplate or check the device management interface for the product name. Confirm it is an SMA Solar Technology blueplanet solar inverter or grid inverter model.Affected if The device is NOT a blueplanet solar/grid inverter from SMA Solar Technology, as the vulnerability only applies to these specific product lines.
-
Check the installed firmware versionAccess the device's web interface, CLI, or management system and locate the firmware version information. Compare it against the affected version thresholds: V6.1.4.9 for newer firmware branches and V3.91 for older branches.Affected if The installed firmware version is below V6.1.4.9 OR below V3.91, depending on which firmware branch the device runs.
-
Verify Technical Service access is enabledCheck the device configuration settings for Technical Service or maintenance access features. Look for options labeled Technical Service, service mode, or remote maintenance access in the device administrative interface.Affected if Technical Service credentials are enabled or accessible on the device, as the vulnerability allows derivation of these specific credentials.
-
Assess serial number exposureReview whether the device serial number is discoverable through the network, device labeling, or public-facing interfaces. Check if the serial number is displayed in the web UI or obtainable via SNMP, API, or network scanning.Affected if The device serial number is discoverable or known to untrusted parties, as this value is required to compute valid Technical Service credentials using the reversible CRC16 algorithm.
A device is affected if it is an SMA blueplanet solar/grid inverter running firmware below V6.1.4.9 (or V3.91 for older branches), has Technical Service functionality enabled, and the device serial number is exposed or discoverable.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
dbcve · scopedContact the vendor (SMA Solar Technology) for firmware updates that implement proper cryptographic credential generation; for affected versions below V6.1.4.9 or V3.91, prioritize patching gridsave models and segregate affected devices on restricted network segments until updates are applied.
V6.1.4.9 or later for TL3 GEN2 devices; V3.91 or later for gridsave devices; contact Siemens for other affected models
- Identify the specific blueplanet device model from the affected products list
- Determine the current firmware version installed on the device
- For TL3 GEN2 devices (blueplanet 100 TL3 GEN2, 105 TL3 GEN2, 125 TL3 GEN2, 150 TL3 GEN2, 155 TL3 GEN2, 165 TL3 GEN2, 87.0 TL3 GEN2, 92.0 TL3 GEN2): upgrade to firmware version V6.1.4.9 or later
- For gridsave devices (blueplanet gridsave 110 TL3-S, 137 TL3-S, 92.0 TL3-S): upgrade to firmware version V3.91 or later
- Contact Siemens technical support to obtain the appropriate firmware update and installation guidance
- After upgrade, verify that Technical Service credentials are no longer derivable from serial numbers
Generated from the published advisory — verify against the referenced sources before acting.
- Consultation4.0 h
- Testing2.0 h
- Review / QA1.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $2,048.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-40946 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-40946 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data