CVE-2025-41647
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedA local, low-privileged attacker can learn the password of the connected controller in PLC Designer V4 due to an incorrect implementation that results in the password being displayed in plain text under special conditions.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · moderate confidenceA local, low-privileged attacker can obtain plaintext passwords of connected controllers in PLC Designer V4 due to an incorrect implementation that exposes passwords under specific conditions.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Local
- Complexity
- Low
- Privileges
- Low
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- None
- Availability
- None
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Verify PLC Designer V4 installationCheck for PLC Designer V4 installation directory and executable (typically under C:\Program Files\ or C:\Program Files (x86)\)Affected if PLC Designer V4 is installed on the system
-
Identify controller configurationsLook for project files or configuration files (.pde, .pcw, or similar) that store connections to PLC controllersAffected if There are saved controller connections or configurations present
-
Locate credential storageSearch for files that may store controller credentials, typically in application data folders (AppData) or within the PLC Designer project directoriesAffected if Files containing controller credentials or passwords are found on disk
-
Inspect password exposureOpen any identified credential files or configuration files and check if passwords are stored in plaintext rather than encrypted or hashedAffected if Passwords for connected controllers are stored in plaintext (readable) format
If PLC Designer V4 is installed with saved controller connections and credentials are stored in plaintext format, the system is affected by this vulnerability.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataApply vendor-supplied patches for PLC Designer V4 when available; in the interim, restrict local access to systems running PLC Designer and monitor for unauthorized access to controller credentials.
- Consultation3.0 h
- Implementation2.0 h
- Testing2.0 h
- Review / QA1.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $2,304.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-41647 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-41647 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data