CVE-2025-4386
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedMedtronic MyCareLink Patient Monitor has an internal serial interface, which allows an attacker with physical access to access a login prompt via a UART terminal.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceThe Medtronic MyCareLink Patient Monitor contains an exposed internal serial (UART) interface that provides direct access to a login prompt. An attacker with physical access to the device can connect to this UART terminal and gain unauthenticated access to the system, potentially allowing further compromise of the patient monitor.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Physical
- Complexity
- Low
- Privileges
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Confirm device modelLocate the device identification label on the Medtronic MyCareLink Patient Monitor (usually on the bottom or rear of the unit) and verify it matches the affected product nameAffected if The device is a Medtronic MyCareLink Patient Monitor and the UART interface is physically accessible
-
Inspect device enclosure for UART accessOpen the device housing (check for screws, clips, or tamper-evident seals) and visually examine the main circuit board for exposed UART pins, test points, or a serial header connector typically arranged in a 3-4 pin configuration (RX, TX, GND, optionally VCC)Affected if UART pins or a serial header are exposed and connectable without requiring special tools or knowledge
-
Test UART interface for authenticationConnect a USB-to-TTL serial adapter to the exposed UART pins (connect adapter ground to board ground, RX to TX, TX to RX), power on the device, and use terminal software (e.g., PuTTY, screen) at common baud rates (115200, 57600, 9600) to observe the boot sequence and login promptAffected if The UART terminal presents a login prompt or shell access without requiring any username or password
-
Check for unauthenticated root accessAfter connecting to the UART terminal, observe whether the system drops directly to a root shell or allows login as root/admin without credentials, or note any default credentials displayed in boot messagesAffected if The UART interface provides root or administrator-level access without authentication
-
Assess physical security controlsExamine the device exterior for security features such as tamper-resistant screws, sealed enclosures, lockable casing, or security stickers that would deter or indicate unauthorized physical access to internalsAffected if The device lacks physical security measures preventing easy access to internal UART interfaces
If physical inspection of a Medtronic MyCareLink Patient Monitor reveals an exposed UART interface that grants unauthenticated shell or root access, the device is affected by this vulnerability.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataDisable or password-protect the UART interface in production firmware, and implement physical security controls to restrict access to the device internals.
- Consultation4.0 h
- Implementation16.0 h
- Testing8.0 h
- Review / QA4.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $8,960.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-4386 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-4386 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm