CWE-272Weakness · CWE-272

CVE-2025-47809

HIGH · 8.2 CVSS v3.1 Published 2025-05-16
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
84/100
Remediation priority · High
Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Wibu CodeMeter before 8.30a sometimes allows privilege escalation immediately after installation (before a logoff or reboot). For exploitation, there must have been an unprivileged installation with UAC, and the CodeMeter Control Center component must be installed, and the CodeMeter Control Center component must not have been restarted. In this scenario, the local user can navigate from Import License to a privileged instance of Windows Explorer.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

Wibu CodeMeter before 8.30a contains a local privilege escalation vulnerability where an unprivileged user who installs the software with UAC can, before performing a required logoff or reboot, navigate through the Import License feature to spawn a privileged instance of Windows Explorer. This exploits the window between installation and system restart where the CodeMeter Control Center component retains elevated privileges.

MitigationUpgrade to CodeMeter version 8.30a or later. Alternatively, ensure immediate logoff or reboot after installation to close the exploitation window, and verify the CodeMeter Control Center component has been restarted before allowing unprivileged access.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Local
Complexity
Low
Privileges
High
User interaction
None
Scope
Changed
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Check installed CodeMeter version
    Open Windows Registry and navigate to HKEY_LOCAL_MACHINE\SOFTWARE\WIBU-SYSTEMS\CodeMeter or check Programs and Features for Wibu CodeMeter entry. Note the version number displayed.
    Affected if The installed version is lower than 8.30a (for example, 8.30, 8.25, 8.20, etc.)
  2. Verify CodeMeter Control Center status
    Open Task Manager, look for CodeMeterCC.exe or CodeMeter Control Center in running processes. Check if the process is running under SYSTEM or elevated privileges.
    Affected if CodeMeter Control Center is running with elevated privileges (NT AUTHORITY\SYSTEM) and you are logged in as a non-administrator user.
  3. Determine time since last restart
    Check System Uptime in Task Manager or run 'systeminfo | find /i "system boot"' to see last boot time. Compare with the CodeMeter installation timestamp from Event Viewer or installation logs.
    Affected if The system has not been restarted or logged off after CodeMeter was installed, leaving the exploitation window open.
  4. Check Import License accessibility
    Launch CodeMeter Control Center (CodeMeterCC.exe) manually. Navigate to the License Import feature. Observe if the feature launches with elevated privileges or spawns an elevated Windows Explorer.
    Affected if The Import License feature launches with elevated privileges accessible to unprivileged users.

You are affected if CodeMeter version is below 8.30a AND the system has not been restarted or logged off since installation, allowing an unprivileged user to access elevated CodeMeter Control Center functions.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Upgrade to CodeMeter version 8.30a or later. Alternatively, ensure immediate logoff or reboot after installation to close the exploitation window, and verify the CodeMeter Control Center component has been restarted before allowing unprivileged access.

Recommended fix High confidence

Wibu CodeMeter 8.30a or later

  1. Verify the current installed version of Wibu CodeMeter by opening CodeMeter Control Center and checking the version information
  2. If the installed version is earlier than 8.30a, download the latest CodeMeter version 8.30a or later from the official Wibu Systems website (www.wibu.com)
  3. Close all running CodeMeter-related applications and services
  4. Run the CodeMeter installer with administrator privileges
  5. Follow the installation wizard prompts to complete the upgrade
  6. After installation completes, restart the computer (or log off and back on) to ensure all CodeMeter services run with proper privileges
  7. Verify the new version is installed correctly by opening CodeMeter Control Center and confirming the version displays 8.30a or higher
  8. Test that the CodeMeter Control Center functions normally after the upgrade
Caveat Standard upgrade - ensure backups of licenses exist before upgrading; verify compatibility with dependent applications after upgrade

Generated from the published advisory — verify against the referenced sources before acting.

Have this fixed Scoped from the published advisory
  • Consultation2.0 h
  • Implementation2.0 h
  • Testing2.0 h
  • Review / QA1.0 h
7.0 hours of engineering $1,240
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $1,984.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2025-47809 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2025-47809 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data