CVE-2025-5022
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedWeak Password Requirements vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit and display unit) to derive the password from the SSID. In addition, if the product is configured to enable the individual air conditioner control function, an attacker who has access to the Wi-Fi communication between the units by exploiting this vulnerability may be able to execute ECHONET Lite commands to perform operations such as turning the air conditioner on or off and changing the set temperature. The individual air conditioner control function is available only in display unit version 02.00.01 or later and measurement unit version 02.03.01 or later. The affected products discontinued in 2015, support ended in 2020.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceThe EcoGuideTAB photovoltaic monitor uses a weak password generation mechanism where the Wi-Fi password is derived from the SSID. An attacker within Wi-Fi range can capture the SSID and mathematically derive the password. If the optional air conditioner control function is enabled (display unit v02.00.01+ and measurement unit v02.03.01+), the attacker can also send ECHONET Lite commands to control HVAC functions.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Adjacent
- Complexity
- Low
- Privileges
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- None
- Availability
- None
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify EcoGuideTAB deviceLocate the photovoltaic monitor device on the network or physically inspect for EcoGuideTAB labelingAffected if The device is an EcoGuideTAB photovoltaic monitor
-
Check display unit firmware versionAccess the device's admin interface or check the firmware version displayed on the display unit screenAffected if Display unit firmware is version 02.00.01 or higher
-
Check measurement unit firmware versionAccess the device's admin interface or check the firmware version displayed on the measurement unitAffected if Measurement unit firmware is version 02.03.01 or higher
-
Verify air conditioner control function statusAccess the device settings menu and check if the optional air conditioner control function is enabledAffected if Air conditioner control function is enabled (requires both display unit v02.00.01+ AND measurement unit v02.03.01+)
You are affected if you have an EcoGuideTAB device with display unit v02.00.01+ and measurement unit v02.03.01+ with the air conditioner control function enabled, making Wi-Fi password derivation and HVAC control possible for nearby attackers
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataThis discontinued product (EOL 2015, support ended 2020) has no vendor patch available. Recommended mitigations include: (1) decommission and replace the device with a supported product, (2) if continued use is required, disable the air conditioner control function and isolate the device on a dedicated network segment VLAN away from critical systems.
- Consultation4.0 h
- Implementation8.0 h
- Testing4.0 h
- Review / QA2.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,120.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-5022 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-5022 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data