CWE-1392Weakness · CWE-1392

CVE-2025-5124

HIGH · 8.1 CVSS v3.1 Published 2025-05-24
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
90/100
Remediation priority · Urgent
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A vulnerability classified as critical has been found in Sony SNC-M1, SNC-M3, SNC-RZ25N, SNC-RZ30N, SNC-DS10, SNC-CS3N and SNC-RX570N up to 1.30. This affects an unknown part of the component Administrative Interface. The manipulation leads to use of default credentials. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. It is recommended to change the configuration settings. The vendor was contacted early about this issue. They confirmed the existence but pointed out that they "have published the 'Hardening Guide' on the Web from July 2018 to January 2025 and have thoroughly informed customers of the recommendation to change their initial passwords".

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

Default credentials vulnerability in Sony IP camera administrative interfaces (SNC-M1, SNC-M3, SNC-RZ25N, SNC-RZ30N, SNC-DS10, SNC-CS3N, SNC-RX570N up to firmware 1.30). Attackers can access the admin interface using factory-default usernames/passwords. The vendor acknowledges the issue but disputes severity, pointing to their Hardening Guide published 2018-2025.

MitigationChange default administrative credentials immediately. For permanent remediation, implement mandatory password changes on first login and eliminate easily guessable default credentials.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
High
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify the camera model
    Access the camera's web interface or check the device label/metadata to confirm the exact model (SNC-M1, SNC-M3, SNC-RZ25N, SNC-RZ30N, SNC-DS10, SNC-CS3N, or SNC-RX570N)
    Affected if The model matches one of the listed affected products
  2. Check the firmware version
    Log into the camera's administrative web interface and navigate to the System or Maintenance section to view the firmware version, or use the camera's API/command interface if available
    Affected if The firmware version is 1.30 or lower (the last unaffected version is not specified, so any version up to and including 1.30 is considered affected)
  3. Verify default credentials status
    Attempt to access the camera's administrative web interface using the documented default username and password combinations for Sony IP cameras (typically admin/admin or root/admin), or check if the credentials have been changed from factory defaults
    Affected if The default username and password still grant administrative access to the camera
  4. Confirm administrative interface accessibility
    Attempt to reach the camera's admin interface via HTTP/HTTPS on the standard management port (typically 80 or 443), or via telnet/SSH if those services are enabled
    Affected if The administrative interface is accessible on the network without requiring non-default credentials
  5. Check if default credentials have been changed
    Review camera configuration settings or security logs to determine if the default administrative password has been modified from the factory default
    Affected if The camera still uses the original factory-default administrative password

The environment is affected if any camera matches one of the listed models (SNC-M1, SNC-M3, SNC-RZ25N, SNC-RZ30N, SNC-DS10, SNC-CS3N, SNC-RX570N) and runs firmware version 1.30 or lower while still accepting factory-default credentials for administrative access.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Change default administrative credentials immediately. For permanent remediation, implement mandatory password changes on first login and eliminate easily guessable default credentials.

Recommended fix High confidence
  1. Access the Sony camera administrative interface via web browser
  2. Locate the user management or password settings in the administration panel
  3. Change the default administrator password to a strong, unique password following the Hardening Guide recommendations
  4. If multiple user accounts exist with default credentials, change all default passwords
  5. Verify the new password works by logging out and logging back in
  6. Disable or change any default guest/test accounts if present

Generated from the published advisory — verify against the referenced sources before acting.

Have this fixed Scoped from the published advisory
  • Consultation4.0 h
  • Implementation16.0 h
  • Testing8.0 h
  • Review / QA4.0 h
32.0 hours of engineering $5,600
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $8,960.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2025-5124 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2025-5124 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data