CWE-335Weakness · CWE-335

CVE-2025-52578

MEDIUM · 5.7 CVSS v3.1 Published 2025-11-18
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
62/100
Remediation priority · Elevated
No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Incorrect Usage of Seeds in Pseudo-Random Number Generator (CWE- 335) vulnerability in the High Sec ELM may allow a sophisticated attacker with physical access, to compromise internal device communications. This issue affects Command Centre Server: 9.30 prior to vCR9.30.251028a (distributed in 9.30.2881 (MR3)), 9.20 prior to vCR9.20.251028a (distributed in 9.20.3265 (MR5)), 9.10 prior to vCR9.10.251028a (distributed in 9.10.4135 (MR8)), all versions of 9.00 and prior.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

A CWE-335 vulnerability exists in the High Sec ELM where the pseudo-random number generator is seeded incorrectly, potentially allowing a sophisticated attacker with physical access to predict random values and compromise internal device communications. This affects Command Centre Server multiple versions (9.30, 9.20, 9.10, and all prior) that interface with the High Sec ELM hardware module.

MitigationApply the vendor-supplied patches: vCR9.30.251028a (distributed in 9.30.2881 MR3), vCR9.20.251028a (distributed in 9.20.3265 MR5), or vCR9.10.251028a (distributed in 9.10.4135 MR8) or later versions to address the PRNG seeding flaw in the High Sec ELM.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Physical
Complexity
High
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
None

CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify installed Command Centre Server version
    Locate the Command Centre Server installation and retrieve its version number (typically found in the application properties, about dialog, or installation directory)
    Affected if The installed version is 9.10, 9.20, 9.30, or any prior version (versions before the patched releases)
  2. Verify High Sec ELM hardware module connection
    Check system configuration, device manager, or Command Centre administration interface for presence of a connected High Sec ELM hardware module
    Affected if A High Sec ELM hardware module is connected and actively interfacing with the Command Centre Server

You are affected if your environment runs any version of Command Centre Server 9.10, 9.20, 9.30, or prior AND has a High Sec ELM hardware module connected and in use.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Apply the vendor-supplied patches: vCR9.30.251028a (distributed in 9.30.2881 MR3), vCR9.20.251028a (distributed in 9.20.3265 MR5), or vCR9.10.251028a (distributed in 9.10.4135 MR8) or later versions to address the PRNG seeding flaw in the High Sec ELM.

Recommended fix High confidence

vCR9.30.251028a (9.30.2881 MR3), vCR9.20.251028a (9.20.3265 MR5), or vCR9.10.251028a (9.10.4135 MR8) depending on your target release

  1. Identify current Command Centre Server version by checking the server or using Command Centre administrative interface
  2. Determine which version branch you are currently on (9.00, 9.10, 9.20, or 9.30)
  3. For version 9.30: upgrade to vCR9.30.251028a (or later, distributed in 9.30.2881 MR3 or higher)
  4. For version 9.20: upgrade to vCR9.20.251028a (or later, distributed in 9.20.3265 MR5 or higher)
  5. For version 9.10: upgrade to vCR9.10.251028a (or later, distributed in 9.10.4135 MR8 or higher)
  6. For version 9.00 or prior: upgrade to a supported version (9.10, 9.20, or 9.30) with the corresponding patch as above
  7. Perform full backup of Command Centre database and configuration before upgrading
  8. Test the upgrade in a non-production environment first
Caveat Review Gallagher release notes for your target version for any configuration or compatibility changes; major version jumps (e.g., from 9.00 to 9.30) may require additional migration steps

Generated from the published advisory — verify against the referenced sources before acting.

Have this fixed Scoped from the published advisory
  • Consultation4.0 h
  • Implementation4.0 h
  • Testing8.0 h
  • Review / QA3.0 h
19.0 hours of engineering $3,260
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,216.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2025-52578 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2025-52578 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data