CWE-402Weakness · CWE-402

CVE-2025-52925

MEDIUM · 5.0 CVSS v3.1 Published 2025-07-02
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
56/100
Remediation priority · Elevated
Remotely reachable Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
In One Identity OneLogin Active Directory Connector before 6.1.5, encryption of the DirectoryToken was mishandled, aka ST-812.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · low confidence

The One Identity OneLogin Active Directory Connector before version 6.1.5 has a vulnerability where encryption of the DirectoryToken (used for authentication/authorization between the connector and OneLogin service) was improperly implemented. This mishandling could allow unauthorized access to sensitive token data, potentially enabling an attacker to gain improper access to the AD integration.

MitigationUpgrade OneLogin Active Directory Connector to version 6.1.5 or later to obtain the patched encryption implementation for the DirectoryToken.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
Low
User interaction
None
Scope
Changed
Confidentiality
Low
Integrity
None
Availability
None

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Verify OneLogin AD Connector is installed
    Check for OneLogin Active Directory Connector service or application on the system. On Windows, look in Programs and Features or Services. On Linux, check for the olad connector process or package.
    Affected if The connector software is not present on the system.
  2. Determine installed version
    Open the OneLogin Active Directory Connector application or access its admin interface. Navigate to the About or Version section typically found in the connector settings or documentation. If using command-line, run: olad --version or check the installer properties.
    Affected if Unable to locate version information.
  3. Compare version to affected range
    Compare the installed version number to 6.1.5. The vulnerability affects all versions before 6.1.5.
    Affected if Installed version is lower than 6.1.5 (for example, 6.1.4, 6.1.0, 6.0.x, etc.).
  4. Verify DirectoryToken configuration exists
    Examine the OneLogin AD Connector configuration files for the DirectoryToken parameter. This token is stored in the connector configuration file (commonly in the installation directory or config folder) and is used for AD integration with OneLogin service.
    Affected if No DirectoryToken configuration is found and the AD connector is not configured for OneLogin integration.
  5. Check for active AD integration
    Confirm the connector is actively managing Active Directory integration. Review the connector status in the OneLogin admin portal or check local configuration for enabled AD domain connections.
    Affected if The connector is not configured with any Active Directory domains.

A user is affected if the OneLogin Active Directory Connector is installed with a version lower than 6.1.5 and has an active DirectoryToken configuration for AD integration.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Upgrade OneLogin Active Directory Connector to version 6.1.5 or later to obtain the patched encryption implementation for the DirectoryToken.

Recommended fix High confidence

One Identity OneLogin Active Directory Connector 6.1.5

  1. Identify current One Identity OneLogin Active Directory Connector version in use
  2. Download One Identity OneLogin Active Directory Connector version 6.1.5 or later from the official One Identity portal or support site
  3. Review the upgrade documentation provided by One Identity for the Active Directory Connector
  4. Execute the upgrade following standard One Identity upgrade procedures
  5. Verify the DirectoryToken encryption is functioning correctly after upgrade
  6. Confirm the connector version is now 6.1.5 or later

Generated from the published advisory — verify against the referenced sources before acting.

Have this fixed Scoped from the published advisory
  • Consultation3.0 h
  • Implementation4.0 h
  • Testing8.0 h
  • Review / QA3.0 h
18.0 hours of engineering $3,060
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $4,896.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2025-52925 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2025-52925 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data