CVE-2025-53831
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedDrawIO for ownCloud is an application for using DrawIO with the file storage, synchronization, and sharing application ownCloud Classic. In DrawIO for ownCloud prior to version 1.0.2, which corresponds to ownCloud 10 prior to version 10.15.3, attackers with access to the DrawIO app can leverage improper neutralization of input during web page generation to achieve stored XSS. Upgrade ownCloud 10 to version 10.15.3 or later or upgrade DrawIO for ownCloud 10 to version 1.0.2 or later to receive a patch.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceThis is a stored Cross-Site Scripting (XSS) vulnerability in the DrawIO for ownCloud app where user-supplied input is not properly sanitized during web page generation. Attackers with access to the DrawIO app can inject malicious JavaScript that executes in the browsers of other users viewing the affected pages.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- Low
- User interaction
- Required
- Scope
- Changed
- Confidentiality
- High
- Integrity
- Low
- Availability
- Low
CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:L/A:L
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Confirm DrawIO for ownCloud app is installedAccess the ownCloud admin panel and navigate to the Apps section to verify if the DrawIO app is listed among installed applicationsAffected if The DrawIO app appears in the installed apps list
-
Identify the DrawIO for ownCloud versionWithin the ownCloud admin panel, view the details or market page for the DrawIO app to read the installed version numberAffected if The installed version is earlier than 1.0.2
-
Confirm ownCloud 10 is in useCheck the ownCloud instance footer or admin overview page to verify the ownCloud server versionAffected if Running ownCloud version 10.x (any minor version before 10.15.3)
-
Verify the DrawIO app is enabledIn the ownCloud admin panel Apps section, confirm the DrawIO app status shows as enabled for user accessAffected if The app is enabled and accessible to users
-
Review recent DrawIO diagrams for suspicious contentAccess the DrawIO app as a user and inspect recently created or edited diagrams, looking for unexpected script tags, event handlers, or encoded content in diagram metadataAffected if Any diagram contains unsanitized HTML or JavaScript in fields that render in the viewer
You are affected if DrawIO for ownCloud versions before 1.0.2 (or ownCloud 10 before 10.15.3) are installed with the app enabled, and users have created diagrams that may contain injected script content
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
dbcve · scopedUpgrade ownCloud 10 to version 10.15.3 or later, or upgrade DrawIO for ownCloud 10 to version 1.0.2 or later, to receive the patch that properly neutralizes input during web page generation.
ownCloud 10.15.3+ or DrawIO for ownCloud 1.0.2+
- Identify which component to upgrade: either ownCloud 10 server or the DrawIO for ownCloud app (or both)
- If upgrading ownCloud 10: Upgrade to version 10.15.3 or later by following ownCloud's upgrade documentation
- If upgrading DrawIO for ownCloud app: Upgrade to version 1.0.2 or later through the ownCloud apps management interface or package manager
- After upgrade, verify the installed version meets the minimum fixed version
- Confirm the DrawIO app functions normally after the upgrade
Generated from the published advisory — verify against the referenced sources before acting.
- Consultation2.0 h
- Implementation2.0 h
- Testing3.0 h
- Review / QA1.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $2,224.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-53831 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-53831 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data