CWE-1247Weakness · CWE-1247

CVE-2025-54520

HIGH · 8.6 CVSS v4.0 Published 2025-09-24
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
91/100
Remediation priority · Urgent
No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Improper Protection Against Voltage and Clock Glitches in FPGA devices, could allow an attacker with physical access to undervolt the platform resulting in a loss of confidentiality.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

This is a hardware vulnerability in FPGA devices where insufficient protection against voltage and clock glitching allows an attacker with physical access to undervolt the platform, potentially causing unintended behavior that leads to loss of confidentiality.

MitigationImplement hardware-level countermeasures such as voltage monitoring circuits, clock glitch detectors, and secure boot with integrity verification to detect and prevent fault injection attacks.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Physical
Complexity
Low
Privileges
None
Authentication
X
User interaction
None
Scope
X

CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify FPGA devices in the environment
    Review hardware asset inventory, system documentation, or use commands like 'lspci' or platform-specific tools to enumerate FPGA devices. Check vendor documentation for the specific FPGA model numbers.
    Affected if FPGA devices are present and no documented voltage or glitch protection mechanisms are specified in the device or system documentation.
  2. Check FPGA security documentation for voltage protection
    Consult the FPGA vendor's security manual or datasheet for the specific model. Look for sections on voltage monitoring, voltage fault injection protection, or undervoltage detection features.
    Affected if The FPGA documentation does not mention voltage monitoring circuits or undervoltage protection as a built-in security feature.
  3. Verify clock glitch detection capability
    Review the FPGA's security configuration guide or security bit settings. Check if the device supports and has enabled clock glitch detection or timing anomaly detection.
    Affected if The FPGA lacks documented clock glitch detection or the feature is not listed as enabled in the security configuration.
  4. Confirm secure boot with integrity verification status
    Examine the system or FPGA configuration to determine if secure boot is enabled and if it includes integrity verification of the bitstream or firmware. Check boot logs or security status registers.
    Affected if Secure boot is not enabled or does not include integrity verification of the FPGA configuration bitstream.
  5. Review voltage and glitch detection logs or alerts
    Check system management logs, FPGA status registers, or any security monitoring tools for voltage anomaly or glitch detection events. Look for alert logs from hardware security modules if present.
    Affected if No voltage anomaly detection logs exist or the system lacks the capability to log such events.

The environment is affected if FPGA devices lack voltage monitoring circuits, clock glitch detectors, and secure boot with integrity verification, or if these protections are documented as absent or disabled.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Implement hardware-level countermeasures such as voltage monitoring circuits, clock glitch detectors, and secure boot with integrity verification to detect and prevent fault injection attacks.

Have this fixed Scoped from the published advisory
  • Consultation16.0 h
  • Implementation40.0 h
  • Testing24.0 h
  • Review / QA12.0 h
92.0 hours of engineering $16,160
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $25,856.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2025-54520 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2025-54520 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data