Maxicharger Ac Elite Business C50 FirmwareOperating system · Autel

CVE-2025-5830

HIGH · 8.8 CVSS v3.0 Published 2025-06-25
Fix available
A fix is available. Upgrade to 1.39.51 / 1.56.51 or later.
See remediation →
93/100
Remediation priority · Urgent
No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Autel MaxiCharger AC Wallbox Commercial DLB_SlaveRegister Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Autel MaxiCharger AC Wallbox Commercial EV chargers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of DLB_SlaveRegister messages. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-26327.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

Heap-based buffer overflow in Autel MaxiCharger AC Wallbox Commercial EV chargers. The DLB_SlaveRegister message handler fails to validate input length before copying user-supplied data into a fixed-size heap buffer, allowing network-adjacent unauthenticated attackers to achieve arbitrary code execution in the device context.

MitigationIsolate EV chargers on a restricted network segment with firewall rules limiting exposure. Apply vendor firmware updates when available. Monitor threat intelligence for this specific device model.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Maxicharger Ac Elite Business C50 FirmwareOperating system
Affected:< 1.39.51< 1.56.51
Maxicharger Ac Pro FirmwareOperating system
Affected:< 1.39.51< 1.56.51
Maxicharger Ac Ultra FirmwareOperating system
Affected:< 1.39.51< 1.56.51
Maxicharger Dc Compact Mobile FirmwareOperating system
Affected:< 1.39.51< 1.56.51
Maxicharger Dc Compact Pedestal FirmwareOperating system
Affected:< 1.39.51< 1.56.51
Maxicharger Dc Fast FirmwareOperating system
Affected:< 1.39.51< 1.56.51
Maxicharger Dc Hipower FirmwareOperating system
Affected:< 1.39.51< 1.56.51
Maxicharger Dh480 FirmwareOperating system
Affected:< 1.39.51< 1.56.51

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Adjacent
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify the MaxiCharger model
    Locate the device label or access the admin web interface to identify the exact model name (e.g., AC Elite Business C50, AC Pro, AC Ultra, DC Compact Mobile, DC Compact Pedestal, DC Fast, DC Hipower, or DH480)
    Affected if The model is any of the listed affected products
  2. Retrieve the firmware version
    Access the device admin interface or check the device label/sticker for the firmware version number
    Affected if The firmware version is below 1.39.51 or below 1.56.51 (note: both version ranges are affected)
  3. Confirm DLB feature is in use
    Check the device configuration for Dynamic Load Balancing (DLB) settings - look for DLB_SlaveRegister or related DLB configuration in the web interface or configuration files
    Affected if DLB is enabled and the device is configured as a DLB slave (the vulnerable code path is in the DLB_SlaveRegister message handler)
  4. Assess network accessibility
    Determine if the charger management port (typically ports 80/443 for web UI and charging protocols) is exposed to untrusted networks or the internet
    Affected if The device is network-adjacent and reachable by unauthenticated attackers from less-trusted networks

The environment is affected if an Autel MaxiCharger model from the affected list is running firmware versions below 1.39.51 or below 1.56.51, has DLB enabled, and is reachable by unauthenticated network attackers.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Upgrade available Upgrade to 1.39.51 / 1.56.51 or later
Fixed in 1.39.511.56.51
Interim mitigation

Isolate EV chargers on a restricted network segment with firewall rules limiting exposure. Apply vendor firmware updates when available. Monitor threat intelligence for this specific device model.

Recommended fix Moderate confidence

Upgrade to firmware version 1.56.51 or later (or minimum 1.39.51 for legacy support)

  1. Identify the specific MaxiCharger model(s) in your environment from the affected product list (AC Elite Business C50, AC Pro, AC Ultra, DC Compact Mobile, DC Compact Pedestal, DC Fast, DC HiPower, DH480)
  2. Check the current firmware version of each device using the device management interface or administrative console
  3. For each device running firmware version < 1.39.51 or < 1.56.51, obtain the latest firmware update from Autel Energy official support channels
  4. Follow Autel's documented firmware upgrade procedure, which typically involves uploading the firmware file through the device's web interface or management system
  5. After upgrade, verify the firmware version has been successfully updated to 1.39.51 or higher (preferably 1.56.51)
  6. Confirm the DLB_SlaveRegister functionality is operational post-upgrade
Caveat Review Autel release notes for any configuration or feature changes between versions; standard practice is to test firmware in controlled environment before production deployment

Generated from the published advisory — verify against the referenced sources before acting.

Fix this in Maxicharger Ac Elite Business C50 Firmware Scoped from the published advisory
  • Consultation4.0 h
  • Implementation6.0 h
  • Testing3.0 h
  • Review / QA2.0 h
15.0 hours of engineering $2,690
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $4,304.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2025-5830 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2025-5830 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data