CWE-656Weakness · CWE-656

CVE-2025-59093

HIGH · 8.5 CVSS v4.0 Published 2026-01-26
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
87/100
Remediation priority · High
Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Exos 9300 instances are using a randomly generated database password to connect to the configured MSSQL server. The password is derived from static random values, which are concatenated to the hostname and a random string that can be read by every user from the registry. This allows an attacker to derive the database password and get authenticated access to the central exos 9300 database as the user Exos9300Common. The user has the roles ExosDialog and ExosDialogDotNet assigned, which are able to read most tables of the database as well as update and insert into many tables.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

Exos 9300 stores a random string in the Windows registry that is used to derive the database password for MSSQL connections. This registry value has weak access controls allowing any local user to read it, enabling derivation of the database password and authentication as the privileged user Exos9300Common with read/write access to most database tables.

MitigationRestrict registry ACLs on the credential storage location to privileged users only, rotate the exposed database password immediately, and migrate credential storage to Windows Credential Manager or DPAPI-protected storage.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Local
Complexity
Low
Privileges
Low
Authentication
X
User interaction
None
Scope
X

CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Verify Exos 9300 installation
    Check Program Files or Program Files (x86) for Exos 9300 directory, or query installed programs for 'Exos 9300'
    Affected if Exos 9300 software is installed on the system
  2. Locate credential registry storage
    Search Windows registry under HKEY_LOCAL_MACHINE\SOFTWARE or HKEY_CURRENT_USER\SOFTWARE for keys containing 'Exos', '9300', 'password', 'credential', or 'database'
    Affected if Registry keys related to Exos 9300 credential storage exist on the system
  3. Identify the random string registry value
    Within Exos-related registry keys, locate any value containing a random alphanumeric string used for password derivation
    Affected if A random string value used for MSSQL password derivation is present in the registry
  4. Check registry value ACLs
    Right-click the identified registry value in regedit, select Permissions, and verify which users have Read access. Use 'Effective Permissions' tab or icacls to enumerate all users with access
    Affected if Non-privileged local users (authenticated users, users group) have Read permission on the registry value containing the credential string
  5. Verify unprivileged read access
    Run reg query on the identified key path as a standard user (non-admin): runas /user:standarduser 'reg query "HKLM\SOFTWARE\...\keypath" /v valuename'
    Affected if A standard (non-admin) local user account can successfully read the registry value containing the credential string

A user is affected if Exos 9300 is installed and any local user with standard privileges can read the registry-stored credential string used to derive the MSSQL database password.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Restrict registry ACLs on the credential storage location to privileged users only, rotate the exposed database password immediately, and migrate credential storage to Windows Credential Manager or DPAPI-protected storage.

Have this fixed Scoped from the published advisory
  • Consultation3.0 h
  • Implementation6.0 h
  • Testing3.0 h
  • Review / QA2.0 h
14.0 hours of engineering $2,490
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $3,984.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2025-59093 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2025-59093 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data