CVE-2025-59109
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedThe dormakaba registration units 9002 (PIN Pad Units) have an exposed UART header on the backside. The PIN pad is sending every button press to the UART interface. An attacker can use the interface to exfiltrate PINs. As the devices are explicitly built as Plug-and-Play to be easily replaced, an attacker is easily able to remove the device, install a hardware implant which connects to the UART and exfiltrates the data exposed via UART to another system (e.g. via WiFi).
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceThe dormakaba 9002 PIN Pad Units expose a UART interface on the device backside that transmits all button presses, including PIN entries, in plaintext. An attacker with physical access can remove the device and attach a hardware implant to the UART header to intercept and exfiltrate sensitive PIN data.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Physical
- Complexity
- Low
- Privileges
- None
- Authentication
- X
- User interaction
- A
- Scope
- X
CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:A/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Inspect device backside for exposed UART headerVisually examine the rear of the dormakaba 9002 PIN Pad Unit for a UART header (typically a 4-6 pin male connector) or any exposed serial interface pinsAffected if A UART header is present and accessible on the device backside
-
Verify UART functionality status in firmwareAccess the device firmware configuration or manufacturing settings to determine if UART interface is enabled or disabled in production firmwareAffected if UART is enabled in the deployed firmware configuration
-
Confirm serial communication encryptionIf UART is active, analyze the data transmitted over the serial interface to determine if PIN data and button presses are encrypted or sent in plaintextAffected if UART transmits button presses or PIN entries without encryption
-
Check physical tamper detection mechanismsInspect the device enclosure for tamper evident seals, tamper detection switches, or other physical security measures designed to detect unauthorized device removalAffected if No tamper detection mechanisms are present or seals are missing or compromised
-
Assess physical access controlsEvaluate the installation environment to determine if the PIN pad unit is installed in a secured area that prevents unauthorized physical access or device removalAffected if The device is installed in an accessible location where an attacker could remove the unit without detection
A user is affected if the dormakaba 9002 PIN Pad Unit has an exposed UART interface that is enabled in firmware and transmits PIN data in plaintext without encryption or physical tamper protection.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataDisable or remove UART functionality in production firmware, implement encryption for any serial communication, and add physical tamper detection or enclosure seals to prevent unauthorized device manipulation.
- Consultation6.0 h
- Implementation30.0 h
- Testing12.0 h
- Review / QA8.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $15,744.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-59109 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-59109 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm