CWE-428Weakness · CWE-428

CVE-2025-59307

MEDIUM · 6.7 CVSS v3.0 Published 2025-09-17
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
69/100
Remediation priority · Elevated
Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
RAID Manager provided by Century Corporation registers a Windows service with an unquoted file path. A user with the write permission on the root directory of the system drive may execute arbitrary code with SYSTEM privilege.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

RAID Manager registers a Windows service with an unquoted file path. This classic unquoted service path vulnerability allows an attacker with write access to the system drive root (e.g., C:\) to place a malicious executable that gets executed by the service with SYSTEM privileges due to Windows path parsing behavior.

MitigationRestrict write permissions on the system drive root directory to prevent path hijacking. The vendor should update the service registration to use quoted paths in the service configuration.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Local
Complexity
Low
Privileges
High
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify RAID Manager service installation
    Open Command Prompt and run: sc query type= service state= all | findstr /i "RAID" to search for RAID Manager related services. Also check the registry under HKLM\SYSTEM\CurrentControlSet\Services for service entries containing 'raid' in the name.
    Affected if No RAID Manager service is found, indicating the product may not be installed.
  2. Retrieve the service binary path
    For each suspected RAID Manager service found, run: sc qc <service_name> and examine the BINARY_PATH_NAME field. The path should be enclosed in quotes if properly configured.
    Affected if The BINARY_PATH_NAME field contains a path without surrounding quotes (e.g., C:\Program Files\RAID Manager\bin\raid.exe instead of "C:\Program Files\RAID Manager\bin\raid.exe").
  3. Parse the unquoted path components
    If the binPath is unquoted, split the path at each space to identify the executable location. For example, C:\Program Files\RAID Manager\raid.exe means the executable is at C:\Program Files\RAID Manager\raid.exe.
    Affected if The first space-separated directory in the path (e.g., C:\Program) exists and is writable by the attacker.
  4. Verify write permissions on the vulnerable path location
    Use icacls from an administrative command prompt on the directory where the service executable resides (the first component of the unquoted path). Run: icacls <directory_path> to list permissions.
    Affected if Users or groups with low-privilege access (especially Everyone, Users, or authenticated users) have write permissions (F) or write-execute (W) permissions on the directory.
  5. Check system drive root writability as attack vector
    Since the vulnerability specifically mentions the system drive root (C:\), verify if the root directory is writable. Run: icacls C:\ and examine if non-admin users have write access.
    Affected if The system drive root directory (C:\) grants write permissions to standard users or low-privilege accounts, allowing path hijacking.

A user is affected if RAID Manager is installed as a Windows service with an unquoted binary path, and the directory containing the service executable (or the system drive root in path traversal scenarios) is writable by low-privilege users.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Restrict write permissions on the system drive root directory to prevent path hijacking. The vendor should update the service registration to use quoted paths in the service configuration.

Have this fixed Scoped from the published advisory
  • Consultation2.0 h
  • Implementation3.0 h
  • Testing2.0 h
  • Review / QA1.0 h
8.0 hours of engineering $1,420
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $2,272.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2025-59307 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2025-59307 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data