CVE-2025-61045
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedTOTOLINK X18 V9.1.0cu.2053_B20230309 was discovered to contain a command injection vulnerability via the mac parameter in the setEasyMeshAgentCfg function.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceA command injection vulnerability exists in TOTOLINK X18 router firmware V9.1.0cu.2053_B20230309. The setEasyMeshAgentCfg function fails to properly sanitize the mac parameter, allowing an attacker to inject and execute arbitrary OS commands on the device.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data= 9.1.0cu.2053_b20230309CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify the device modelAccess the router's web interface or check the device label to confirm it is a TOTOLINK X18 routerAffected if Device is not a TOTOLINK X18 model
-
Check the firmware versionLog into the router admin panel, go to System Status or Firmware Upgrade page, and record the installed firmware version stringAffected if Firmware version is exactly 9.1.0cu.2053_b20230309
-
Verify EasyMesh functionality is accessibleCheck if the router's web interface exposes EasyMesh or mesh network configuration settings (usually under Wireless or Network settings)Affected if EasyMesh or mesh network configuration interface is available and enabled
-
Check for the vulnerable parameter exposureInspect HTTP requests to the router's CGI endpoints or check if the setEasyMeshAgentCfg function is exposed via the web interface APIAffected if The setEasyMeshAgentCfg function or mac parameter input is accessible through the management interface
You are affected if the device is a TOTOLINK X18 running firmware version 9.1.0cu.2053_b20230309 and the EasyMesh configuration interface is accessible.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataApply vendor firmware patch if available; otherwise segment the device network and disable untrusted management interfaces to reduce attack surface.
- Consultation4.0 h
- Implementation8.0 h
- Testing4.0 h
- Review / QA3.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,408.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-61045 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-61045 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data