CWE-124Weakness · CWE-124

CVE-2025-61690

HIGH · 7.8 CVSS v3.1 Published 2025-10-02
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
81/100
Remediation priority · High
No privileges

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
KV STUDIO versions 12.23 and prior contain a buffer underflow vulnerability. If the product uses a specially crafted file, arbitrary code may be executed on the affected product.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

KV STUDIO versions 12.23 and prior contain a buffer underflow vulnerability that can be triggered when the product processes a specially crafted file, potentially allowing arbitrary code execution on the affected system.

MitigationUpdate KV STUDIO to a version later than 12.23. Until an update is available, avoid opening untrusted or specially crafted files with the software.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Local
Complexity
Low
Privileges
None
User interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Confirm KV STUDIO installation
    Locate KV STUDIO on the system by searching program files, installation directories, or system registry entries for KV STUDIO
    Affected if KV STUDIO is not found on the system, the vulnerability does not apply
  2. Identify installed KV STUDIO version
    Use the product's built-in version check (typically via Help > About, or right-click the executable and select Properties > Details), or check the version information in the installation directory
    Affected if Unable to determine the version - assume affected if product is present
  3. Compare version to CVE threshold
    Compare the installed version number to 12.23 - check if the installed version is 12.23 or any version prior to 12.23
    Affected if Installed version is 12.23 or lower (for example, 12.22, 12.21, 12.0, etc.)
  4. Verify file processing exposure
    Determine if the system regularly opens or processes files with KV STUDIO, particularly from external or untrusted sources
    Affected if KV STUDIO is used to open files from untrusted or unknown sources and the version is 12.23 or prior

The environment is affected if KV STUDIO version 12.23 or any earlier version is installed and the software is used to process files.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Update KV STUDIO to a version later than 12.23. Until an update is available, avoid opening untrusted or specially crafted files with the software.

Have this fixed Scoped from the published advisory
  • Consultation4.0 h
  • Implementation8.0 h
  • Testing6.0 h
  • Review / QA4.0 h
22.0 hours of engineering $3,860
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $6,176.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2025-61690 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2025-61690 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data