CVE-2025-6185
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedLeviton AcquiSuite and Energy Monitoring Hub are susceptible to a cross-site scripting vulnerability, allowing an attacker to craft a malicious payload in URL parameters, which would execute in a client browser when accessed by a user, steal session tokens, and control the service.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceA reflected cross-site scripting (XSS) vulnerability in Leviton AcquiSuite and Energy Monitoring Hub allows attackers to inject malicious JavaScript code through URL parameters. When users access crafted malicious URLs, the payload executes in their browsers, enabling session token theft and potential service control.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- User interaction
- Required
- Scope
- Changed
- Confidentiality
- High
- Integrity
- High
- Availability
- None
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:N
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify the installed productAccess the web interface login page or system information panel to confirm whether the device is running Leviton AcquiSuite or Energy Monitoring Hub software.Affected if The product is Leviton AcquiSuite or Energy Monitoring Hub.
-
Determine the firmware/software versionLocate the version information in the web interface (typically under About, System Info, or Settings sections) or check the device management console for the installed version number.Affected if The installed version falls within the affected range and has not been patched.
-
Verify web interface accessibilityConfirm that the web interface is accessible on the network by attempting to reach the device IP or hostname over HTTP/HTTPS.Affected if The web interface is exposed and reachable on the network.
-
Inspect URL parameter handlingUse a browser developer tool or intercepting proxy to examine how the web application handles URL parameters. Submit test input in URL query strings and observe whether the input is reflected back in the response without proper encoding.Affected if URL parameters are reflected in the response without encoding, indicating potential XSS vulnerability.
If the system is Leviton AcquiSuite or Energy Monitoring Hub with an unpatched version and the web interface is accessible, the stored XSS vulnerability in URL parameters is likely present.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataImplement strict input validation and output encoding on all URL parameters, and deploy Content-Security-Policy headers to block inline script execution.
- Consultation3.0 h
- Implementation6.0 h
- Testing3.0 h
- Review / QA2.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $3,984.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-6185 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-6185 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data