CVE-2025-61910
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedThe NASA’s Interplanetary Overlay Network (ION) is an implementation of Delay/Disruption Tolerant Networking (DTN). A BPv7 bundle with a malformed extension block causes uncontrolled memory allocation inside ION-DTN 4.1.3s, leading to receiver thread termination and a Denial-of-Service (DoS). The triggering bundle contains an extension block starting at `0x85070201005bbb0e20b4ea001a000927c0...`. The first byte in the extension block (0x85) indicates a CBOR array of five elements of which the first four are numbers (0x07, 0x02, 0x01, 0x00) but the fifth element is a byte string of length 27 (`0x5bbb0e20b4ea001a000927c0...`). The vulnerability seems to be due to processing the fifth element of the array (i.e., the byte string) as replacing it with a number makes the vulnerability no longer be triggered. While parsing this extension block, ION obtains a very large block length, which in the code in `bei.c`:764) seems to be passed from `blockLength` which is an unsigned int, to a 32 bit signed integer `blkSize`. The unsigned to signed conversion causes `blkSize` to hold the value of -369092043, which is then converted into a 64-bit unsigned value inside `MTAKE(blkSize)`, resulting in an attempt to allocate an unrealistic amount of memory, causing the error. As of time of publication, no known patched versions of BPv7 exist.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceION-DTN 4.1.3s suffers from a memory allocation vulnerability when parsing malformed BPv7 bundles with specifically crafted extension blocks. The bug occurs in bei.c:764 where an unsigned int `blockLength` is assigned to a signed int `blkSize`, causing a negative value (-369092043) due to integer overflow. This negative value is then passed to MTAKE() which interprets it as a large 64-bit unsigned value, triggering excessive memory allocation and causing the receiver thread to terminate, resulting in DoS.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- None
- Integrity
- None
- Availability
- High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Check ION-DTN installation and versionRun 'ionversion' or check package manager for ION-DTN version. Compare against 4.1.3s.Affected if ION-DTN version is 4.1.3s and the software handles incoming BPv7 bundles
-
Verify BPv7 bundle reception is enabledCheck ION configuration files (typically in /opt/ion or /etc/ion) for BPv7 reception settings, or examine running ion processes with 'ps aux | grep ion' and review config for bundle reception.Affected if BPv7 bundle reception is enabled and the system accepts bundles from untrusted sources
-
Inspect bei.c for vulnerable code patternIf source code is available, locate bei.c and examine line 764 where blkSize receives blockLength. Look for unsigned-to-signed int assignment without bounds checking.Affected if The vulnerable assignment pattern exists in bei.c:764 without proper integer overflow protection
-
Monitor for MTAKE allocation failuresReview system logs (/var/log/messages, syslog) or ION-specific logs for MTAKE failure messages or memory allocation errors occurring during bundle reception.Affected if MTAKE failures or excessive memory allocation errors appear in logs when receiving bundles
-
Check network exposure to untrusted BPv7 sourcesReview firewall rules and network segmentation. Identify if ION-DTN节点 directly accepts BPv7 bundles from untrusted network endpoints.Affected if ION-DTN is directly exposed to untrusted networks without input validation at the CBOR parsing layer
A system is affected if it runs ION-DTN 4.1.3s, has BPv7 bundle reception enabled, and processes BPv7 bundles from potentially untrusted sources without additional input validation layers.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataSince no patched version exists, implement input validation at the CBOR parsing layer to verify block lengths before conversion, add bounds checking between unsigned and signed integer assignments, and consider network segmentation to limit exposure to untrusted BPv7 bundles until an official patch is available.
- Consultation6.0 h
- Implementation12.0 h
- Testing8.0 h
- Review / QA4.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $8,448.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-61910 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-61910 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm