Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedA heap-based buffer overflow in the ionic cloud driver for VMware ESXi could allow an attacker to achieve privilege escalation, potentially resulting in arbitrary code execution.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · moderate confidenceA heap-based buffer overflow vulnerability exists in the ionic cloud driver for VMware ESXi. This driver-level flaw allows a local or adjacent attacker to perform privilege escalation, potentially executing arbitrary code with elevated privileges on the hypervisor.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Local
- Complexity
- High
- Privileges
- Low
- Authentication
- X
- User interaction
- None
- Scope
- X
CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify if ionic cloud driver is loaded on ESXi hostRun 'esxcli system module list' or check /etc/vmware/esx.conf for ionic driver entries to see if the ionic cloud driver module is loadedAffected if ionic cloud driver module is present and loaded on the ESXi host
-
Determine ESXi host versionRun 'vmware -v' or check the Summary tab in vSphere Client to obtain the full ESXi version build numberAffected if ESXi version falls within any affected range (compare against official VMware advisory when released)
-
Check ionic driver versionRun 'esxcli system module get -m ionic' to retrieve the ionic cloud driver module version informationAffected if ionic driver version is lower than the patched version in the VMware advisory
-
Review driver configuration and usageCheck 'esxcli network nic list' and inspect any VMkernel adapters or cloud configurations that utilize the ionic driver for network or storage cloud connectivityAffected if The ionic driver is actively configured or in use for cloud storage/networking operations
-
Audit host access and adjacent network exposureReview ESXi host management network access controls and verify whether untrusted local or adjacent network attackers could reach the ESXi management interfaceAffected if Host has permissive access controls allowing local or adjacent attackers to interact with the ionic driver interface
The environment is affected if an ESXi host has the ionic cloud driver loaded and running a version below the patched version specified in the VMware security advisory for CVE-2025-62624.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataApply the official VMware patch for the ionic cloud driver when released; verify ESXi versions in use and implement the update during a scheduled maintenance window.
- Consultation4.0 h
- Implementation6.0 h
- Testing6.0 h
- Review / QA3.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,312.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-62624 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-62624 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data