CVE-2025-64507
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedIncus is a system container and virtual machine manager. An issue in versions prior to 6.0.6 and 6.19.0 affects any Incus user in an environment where an unprivileged user may have root access to a container with an attached custom storage volume that has the `security.shifted` property set to `true` as well as access to the host as an unprivileged user. The most common case for this would be systems using `incus-user` with the less privileged `incus` group to provide unprivileged users with an isolated restricted access to Incus. Such users may be able to create a custom storage volume with the necessary property (depending on kernel and filesystem support) and can then write a setuid binary from within the container which can be executed as an unprivileged user on the host to gain root privileges. A patch for this issue is expected in versions 6.0.6 and 6.19.0. As a workaround, permissions can be manually restricted until a patched version of Incus is deployed.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysisPrivileges are granted, or fail to be dropped, incorrectly, so an action runs with more power than it should. An attacker who reaches that path inherits the excess privilege. The fix is least-privilege throughout, with explicit, checked transitions whenever privilege changes.
General guidance for the improper privilege management class — the official description and references above are authoritative for this specific CVE. Want a bespoke review and a reviewed fix? Ask our team →
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data< 6.0.6>= 6.1.0, < 6.19.0CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Local
- Complexity
- Low
- Privileges
- Low
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
dbcve · scoped6.0.66.19.0
Upgrade to Incus 6.0.6 (if currently <6.0.6) or Incus 6.19.0 (if currently >=6.1.0 and <6.19.0)
- Identify the current Incus version using `incus version` or `incus admin info`
- Determine which upgrade path applies: if current version < 6.0.6, upgrade to 6.0.6; if current version is >= 6.1.0 and < 6.19.0, upgrade to 6.19.0
- Upgrade Incus using the distribution's package manager (e.g., `apt update && apt install incus` for Debian/Ubuntu, or equivalent for other distributions)
- Verify the new version is installed: `incus version`
- Confirm the upgrade completed successfully: `incus admin info`
- As a temporary mitigation until upgrade: restrict which users can create custom storage volumes with `security.shifted=true` by reviewing storage pool configurations and removing unnecessary permissions from the `incus` group
Generated from the published advisory — verify against the referenced sources before acting.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-64507 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-64507 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data