CVE-2025-6561
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedCertain hybrid DVR models ((HBF-09KD and HBF-16NK)) from Hunt Electronic have an Exposure of Sensitive Information vulnerability, allowing unauthenticated remote attackers to directly access a system configuration file and obtain plaintext administrator credentials.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceThe Hunt Electronic hybrid DVR models HBF-09KD and HBF-16NK contain an unauthenticated information disclosure vulnerability that allows remote attackers to directly access a system configuration file containing plaintext administrator credentials. This critical flaw requires no authentication and can be exploited remotely, giving attackers full administrative access to the affected DVR systems.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify the DVR modelAccess the device web interface or check the physical device label for the exact model number. Common endpoints like /config or system info pages may display the model.Affected if The model is HBF-09KD or HBF-16NK
-
Verify firmware versionCheck the device's system information page or firmware version endpoint. Compare against any available version information from Hunt Electronic.Affected if The firmware version matches the affected model line (HBF-09KD or HBF-16NK)
-
Confirm network accessibilityDetermine if the device's web interface or management ports (typically HTTP/HTTPS on 80/443) are reachable from untrusted networks. Use a port scan or attempt to access the device IP from an external location.Affected if The device management interface is exposed to the internet or untrusted networks without firewall protection
-
Test for unauthenticated config accessAttempt to access common configuration file paths such as /config/system.ini, /config.cfg, or similar paths that may expose system configuration. These may be accessible via HTTP without credentials.Affected if The configuration file or system settings are accessible without any authentication
You are affected if you operate a Hunt Electronic HBF-09KD or HBF-16NK DVR with its management interface exposed to network access, and the system configuration file or credentials are retrievable without authentication.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataImmediately restrict network exposure of affected DVRs, change all administrative credentials, and contact Hunt Electronic for firmware patches. If no patch is available, isolate these devices behind a firewall or consider replacement.
- Consultation4.0 h
- Implementation8.0 h
- Testing3.0 h
- Review / QA2.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $4,880.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-6561 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-6561 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data