CVE-2025-69011
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedImproper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in WPKube Cool Tag Cloud cool-tag-cloud allows Stored XSS.This issue affects Cool Tag Cloud: from n/a through <= 2.29.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceStored Cross-site Scripting (XSS) vulnerability in the WPKube Cool Tag Cloud WordPress plugin allows authenticated attackers to inject malicious JavaScript scripts through plugin input fields that are not properly sanitized before being stored and rendered in web pages.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- Low
- User interaction
- Required
- Scope
- Changed
- Confidentiality
- Low
- Integrity
- Low
- Availability
- Low
CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:L
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Confirm Cool Tag Cloud plugin is installedNavigate to WordPress admin > Plugins > Installed Plugins and search for 'Cool Tag Cloud' or 'WPKube Cool Tag Cloud'. Note whether the plugin appears in the list.Affected if The plugin is installed on the WordPress site
-
Check the installed plugin versionIn the Plugins list, locate Cool Tag Cloud and view the version number displayed beneath the plugin name. Compare this version to the fixed version 2.30.Affected if The installed version is lower than 2.30 (vulnerable versions)
-
Verify the plugin is activeIn WordPress admin > Plugins, check if Cool Tag Cloud shows as 'Active'. Inactive plugins do not execute their code and are not vulnerable.Affected if The plugin is active and running
-
Inspect plugin settings for suspicious stored contentGo to the plugin's settings page (usually under Settings or the plugin's own menu). Review any tag, label, or text input fields for unexpected script tags, JavaScript: URLs, or onload/onerror event handlers that were not intentionally added.Affected if Stored XSS payloads are present in plugin configuration fields
-
Check user role access to plugin settingsNavigate to WordPress admin > Users > Roles or use a role management plugin to see which user roles have access to the Cool Tag Cloud settings page. Look for contributors, authors, or editors who should not have plugin configuration access.Affected if Lower-privileged users (subscriber, contributor, author) can access or modify plugin settings
The environment is affected if the Cool Tag Cloud plugin is installed, active, and running a version lower than 2.30, or if unexpected script content is found stored in the plugin's configuration fields.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataApply the latest plugin update (version 2.30 or higher) which includes proper input sanitization and output encoding to neutralize malicious scripts. Until patched, restrict administrator access and monitor for suspicious payload submissions.
- Consultation2.0 h
- Implementation4.0 h
- Testing3.0 h
- Review / QA2.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $3,088.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-69011 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-69011 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data