CVE-2025-69362
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedImproper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in POSIMYTH UiChemy uichemy allows Stored XSS.This issue affects UiChemy: from n/a through <= 4.4.2.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceThe UiChemy plugin for Elementor contains a stored cross-site scripting (XSS) vulnerability due to improper neutralization of user-supplied input. Attackers can inject malicious JavaScript scripts that persist in the database and execute when other users view affected pages in the WordPress admin or frontend.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- High
- User interaction
- Required
- Scope
- Changed
- Confidentiality
- Low
- Integrity
- Low
- Availability
- Low
CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:L
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Confirm UiChemy plugin installationNavigate to WordPress admin > Plugins and verify UiChemy is listed as installed and activeAffected if UiChemy plugin is not installed or not active - not affected
-
Identify installed UiChemy versionIn WordPress admin > Plugins, find UiChemy and note the version number displayed; compare against any known fixed versionAffected if Unable to determine version or version is older than fixed release - potentially affected
-
Locate user input points in UiChemyCheck UiChemy plugin settings, export/import functionality, or template creation areas where user-supplied data can be saved to the databaseAffected if Plugin allows user-generated content without visible sanitization controls - affected if data persists in database
-
Verify stored data rendering without encodingExamine pages where UiChemy data displays in admin or frontend; inspect page source to see if user input is rendered with proper HTML entity encodingAffected if User-supplied content renders as raw HTML/JavaScript without encoding - confirmed affected
The environment is affected if the UiChemy plugin for Elementor is installed and active, with any user-accessible input fields that store data to the database and render it without proper output encoding.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataUpdate to the latest version of UiChemy when available, or apply input sanitization and output encoding fixes to all user-supplied data before rendering in HTML contexts.
- Consultation1.0 h
- Implementation2.0 h
- Testing2.0 h
- Review / QA1.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $1,664.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-69362 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-69362 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data