CadimageApplication · Cadsofttools

CVE-2025-7308

HIGH · 7.8 CVSS v3.0 Published 2025-07-21
Fix available
A fix is available. Upgrade to 15.0.0.8 or later.
See remediation →
81/100
Remediation priority · High
No privileges

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
IrfanView CADImage Plugin DWG File Parsing Memory Corruption Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of IrfanView CADImage Plugin. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DWG files. The issue results from the lack of proper validation of user-supplied data, which can result in a memory corruption condition. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-26389.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

The CADImage plugin in IrfanView lacks proper validation of user-supplied data during DWG file parsing, leading to memory corruption that can be leveraged for remote code execution in the context of the current process. Exploitation requires a user to open a malicious DWG file.

MitigationAvoid opening untrusted DWG files and monitor for updates to the CADImage plugin that address this validation vulnerability.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
CadimageApplication
Affected:< 15.0.0.8

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Local
Complexity
Low
Privileges
None
User interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Locate the CADImage plugin file
    Check the IrfanView installation directory (typically in a subfolder named 'plugins') for a DLL file related to CADImage or CAD handling. Common names include CadImage.dll, cadimage.dll, or similar.
    Affected if The CADImage plugin DLL exists in the IrfanView plugins folder
  2. Check the plugin file version
    Right-click the CADImage DLL file, select Properties, then view the Details tab to find the File Version or Product Version field.
    Affected if The version number displayed is lower than 15.0.0.8
  3. Confirm DWG file association is enabled
    In IrfanView, go to Options > Properties/Settings > Plugins to verify the CADImage plugin is loaded and enabled for DWG file handling.
    Affected if The plugin is listed as loaded/enabled and configured to handle DWG files
  4. Verify IrfanView processes DWG files
    Try to open a DWG file in IrfanView or check File > Open to see if DWG appears in the supported file types dropdown.
    Affected if IrfanView can open DWG files using the CADImage plugin

If the CADImage plugin is installed with a version below 15.0.0.8 and is enabled for DWG file handling, the environment is affected by this vulnerability.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Upgrade available Upgrade to 15.0.0.8 or later
Fixed in 15.0.0.8
Interim mitigation

Avoid opening untrusted DWG files and monitor for updates to the CADImage plugin that address this validation vulnerability.

Recommended fix High confidence

Cadimage 15.0.0.8 or later

  1. Identify the current Cadimage plugin version installed with IrfanView (check plugin folder or IrfanView > About > Plugins)
  2. Close IrfanView completely if it is currently running
  3. Download the Cadimage plugin version 15.0.0.8 or later from the official CADImage vendor website or authorized distributor
  4. Install or upgrade the Cadimage plugin to version 15.0.0.8 or later following the vendor installation instructions
  5. Verify the installed version shows 15.0.0.8 or later after installation completes
  6. Restart IrfanView and confirm the CADImage plugin loads correctly

Generated from the published advisory — verify against the referenced sources before acting.

Fix this in Cadimage Scoped from the published advisory
  • Consultation3.0 h
  • Implementation6.0 h
  • Testing4.0 h
  • Review / QA2.0 h
15.0 hours of engineering $2,640
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $4,224.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2025-7308 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2025-7308 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data