CWE-126Weakness · CWE-126

CVE-2025-7745

MEDIUM · 5.8 CVSS v3.1 Published 2025-07-24
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
67/100
Remediation priority · Elevated
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Buffer Over-read vulnerability in ABB AC500 V2.This issue affects AC500 V2: through 2.5.2.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · low confidence

A buffer over-read vulnerability exists in ABB AC500 V2 PLC firmware versions up to and including 2.5.2. This memory safety issue allows reading beyond allocated buffer boundaries, potentially exposing sensitive information or causing unpredictable behavior in the industrial controller.

MitigationUpdate ABB AC500 V2 firmware to a patched version beyond 2.5.2 when available. If no patch exists, implement network segmentation to isolate the PLC and monitor for anomalous behavior.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Scope
Changed
Confidentiality
Low
Integrity
None
Availability
None

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Confirm ABB AC500 V2 model
    Identify the PLC model as ABB AC500 V2 through the device nameplate, web interface login page, or engineering software (Control Builder Plus) project settings
    Affected if Device is not an ABB AC500 V2 PLC
  2. Determine firmware version
    Retrieve the installed firmware version via the PLC web interface (typically at / or System > Information), the Control Builder Plus engineering software, or by connecting to the controller via FTP/Telnet and querying the system
    Affected if Firmware version cannot be determined
  3. Compare against affected versions
    Compare the retrieved firmware version number to the affected range: all versions up to and including 2.5.2
    Affected if Firmware version is 2.5.2 or any earlier version (e.g., 2.5.1, 2.5.0, 2.4.x)
  4. Check for available patches
    Check ABB support channels or the firmware download area for any version newer than 2.5.2 that may contain the fix
    Affected if No patched firmware version beyond 2.5.2 is available or installed

The environment is affected if an ABB AC500 V2 PLC is running firmware version 2.5.2 or any earlier version.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Update ABB AC500 V2 firmware to a patched version beyond 2.5.2 when available. If no patch exists, implement network segmentation to isolate the PLC and monitor for anomalous behavior.

Have this fixed Scoped from the published advisory
  • Consultation6.0 h
  • Implementation12.0 h
  • Testing10.0 h
  • Review / QA4.0 h
32.0 hours of engineering $5,580
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $8,928.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2025-7745 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2025-7745 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data