CWE-250Weakness · CWE-250

CVE-2025-8907

HIGH · 7.0 CVSS v3.1 Published 2025-08-13
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
72/100
Remediation priority · Elevated
Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A vulnerability was found in H3C M2 NAS V100R006. Affected by this vulnerability is an unknown functionality of the component Webserver Configuration. The manipulation leads to execution with unnecessary privileges. An attack has to be approached locally. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The vendor explains: "[T]he device only has configuration files and does not actually have boa functionality. It is impossible to access or upload files anonymously to the device through boa services". This vulnerability only affects products that are no longer supported by the maintainer.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

Local privilege escalation vulnerability in the Webserver Configuration component of H3C M2 NAS V100R006. An attacker with local access can manipulate the boa webserver configuration to gain elevated privileges. However, the vendor notes that the affected boa service does not actually function on this device, and the product is end-of-life.

MitigationSince the product is no longer supported and the vulnerable component does not function, retire and replace the affected device. If continued use is unavoidable, apply strict network isolation and limit local access to trusted personnel only.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Local
Complexity
High
Privileges
Low
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify H3C M2 NAS model and firmware version
    Access the device management interface or check the system information page to confirm the product is H3C M2 NAS running firmware version V100R006.
    Affected if The device is an H3C M2 NAS with firmware V100R006 installed.
  2. Locate boa webserver configuration files
    Search the filesystem for boa-related configuration files, typically found in /etc/boa/ or similar directories. Use commands like 'find / -name boa* 2>/dev/null' or check common webserver configuration paths.
    Affected if Boa webserver configuration files exist on the device.
  3. Verify boa service status
    Check if the boa service is running or enabled on the device. Use commands such as 'ps aux | grep boa' or check init/systemd service listings for any boa-related service.
    Affected if The boa service is actively running or configured to start on boot.
  4. Examine boa configuration file permissions
    Inspect permissions on any found boa configuration files (typically boa.conf). Use 'ls -la /etc/boa/boa.conf' or equivalent paths to check if non-privileged users can modify these files.
    Affected if Boa configuration files are writable by low-privilege users or users in the 'nobody' or 'www-data' groups.
  5. Check for webserver configuration interface access
    If a web interface exists, navigate to the Webserver Configuration section to verify whether boa can be configured. Note: The vendor states this service does not function on this device.
    Affected if The Webserver Configuration feature is accessible and functional in the device management interface.

A user is affected only if they have an H3C M2 NAS at firmware V100R006 with the boa webserver service present, running, and its configuration files accessible to low-privilege users; however, the vendor explicitly states the vulnerable boa service does not actually function on this device.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Since the product is no longer supported and the vulnerable component does not function, retire and replace the affected device. If continued use is unavoidable, apply strict network isolation and limit local access to trusted personnel only.

Recommended fix Low confidence
  1. Document this CVE as a known issue for H3C M2 NAS V100R006 since the product is end-of-life and no longer supported by the vendor.
  2. Consider decommissioning or replacing the affected H3C M2 NAS device if continued use is required, as no patches or upgrades are available.
  3. Implement network segmentation to limit local access to the device if continued operation is necessary.
  4. Monitor vendor communications for any potential future security advisories, though the vendor has indicated the product is unsupported.
Caveat No upgrade available - product is end-of-life and vendor has stated it is no longer supported

Generated from the published advisory — verify against the referenced sources before acting.

Have this fixed Scoped from the published advisory
  • Consultation2.0 h
  • Implementation4.0 h
  • Testing2.0 h
  • Review / QA1.0 h
9.0 hours of engineering $1,600
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $2,560.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2025-8907 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2025-8907 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data