CWE-250Weakness · CWE-250

CVE-2025-9055

MEDIUM · 6.4 CVSS v3.1 Published 2025-11-11
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
66/100
Remediation priority · Elevated
Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
The VAPIX Edge storage API that allowed a privilege escalation, enabling a VAPIX administrator-privileged user to gain Linux Root privileges. This flaw can only be exploited after authenticating with an administrator-privileged service account.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

A privilege escalation vulnerability exists in the VAPIX Edge storage API on Axis Communications devices. An authenticated user with administrator-level privileges can exploit this flaw to gain Linux Root access to the underlying operating system. The attack requires prior authentication with an administrator-privileged service account.

MitigationApply the vendor-supplied firmware patch from Axis Communications when available, and restrict administrator-level VAPIX accounts to trusted personnel only until the update is deployed.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Local
Complexity
High
Privileges
High
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Confirm Axis Communications device
    Check device model via web interface, system info page, or physical label
    Affected if Device is an Axis Communications network product with VAPIX framework
  2. Identify VAPIX Edge storage API configuration
    Access device web interface > Storage > Edge Storage settings, or query VAPIX API endpoint /axis-cgi/storage.cgi
    Affected if Edge Storage feature is enabled and configured on the device
  3. Review VAPIX administrator accounts
    Access Settings > Users in web interface, or query /axis-cgi/admin/user.cgi?action=list, check for accounts with Administrator privileges
    Affected if There are administrator-level VAPIX service accounts configured on the device
  4. Check network exposure of VAPIX interface
    Review device network settings and firewall rules; determine if VAPIX HTTP/HTTPS ports (80/443) are accessible from untrusted networks
    Affected if VAPIX interface is exposed to the internet or untrusted LAN segments where compromised accounts could be leveraged
  5. Verify firmware version
    Access System > About in web interface, or query /axis-cgi/admin/system.cgi?action=systeminfo to retrieve firmware version
    Affected if Firmware version is older than the vendor patched version (specific version available from Axis security advisory)
  6. Audit VAPIX access logs for suspicious activity
    Review VAPIX logs at System > Logs > Access Logs, look for Edge Storage API calls from administrator accounts followed by unusual system commands
    Affected if Logs show Edge Storage API activity from administrator accounts that may indicate exploitation attempts

User is affected if this is an Axis device with VAPIX Edge storage API enabled and administrator-level VAPIX accounts exist, especially if the device is network-accessible to untrusted users and runs unpatched firmware.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Apply the vendor-supplied firmware patch from Axis Communications when available, and restrict administrator-level VAPIX accounts to trusted personnel only until the update is deployed.

Have this fixed Scoped from the published advisory
  • Consultation4.0 h
  • Implementation2.0 h
  • Testing2.0 h
  • Review / QA1.0 h
9.0 hours of engineering $1,640
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $2,624.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2025-9055 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2025-9055 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data